NewAir APH-4000PV Benutzerhandbuch

Seite von 15
                      
10 
 
 
2.2 Minimum clearances  
 
Minimum 24” clearances from combustible materials must be maintained at 
all times while the heater is in operation. 
 
3. Operation 
 
3.1 Preparation before lighting 
 
3.1.1 Check any possible shipping damage of the heater. If any is found,   
         immediately contact your selling dealer or call us directly.  
3.1.2 Please review thoroughly and be sure you understand all of the “safety  
         precautions and warnings”. 
3.1.3 Make sure control knob is at “OFF” position. 
3.1.4 Place the LP cylinder onto the Cylinder Base.  Connect the Regulator /  
         hose assembly to the cylinder by rotating the Regulator’s hand wheel   
         clockwise into the cylinder’s valve and securely tighten.   
3.1.5 If attempting to relight a hot heater, always wait until the heater is cool. 
 
3.2 Leak Checking 
 
Check all of gas connections in the heater with soapy water.  
Apply soap solution to all propane connections, especially the fuel connections  
between the Regulator connection device to the Cylinder valve,  the fitting at 
the end of the Fuel Line to the Burner Head and the other end of the Fuel Line 
to the Hose assembly.  
  Inspect all propane connections, look for bubbles. 
If bubbles appear, there is a leak. Disconnect and reconnect, try again. 
  If no bubbles appear, the connection is safe, continue the next step: Lighting. 
  If the leak persists, turn cylinder valve OFF and contact your selling
 dealer or  
     call our Customer Service Dept. directly for assistance 
and advice. 
 
Warning: 
  
Perform Leak test outdoors only.
 
Never leak test when smoking.
 
Do not use a flame to check for leaks. 
 
3.3 Lighting 
 
3.3.1 To light the pilot 
 
Lift the cylinder cover from the base and set it the stable position. Turn the  
    cylinder valve on.
 
 The first step is to purge the fuel line when a new or refilled propane cylinder is  
    installed.  
 Gently depress the control knob at the faceplate panel and rotate it to “PILOT”