NewAir APH-4000PV Benutzerhandbuch

Seite von 15
                      
 
 
                                                                                             
 
 
Step 8.
 Connect an approved propane cylinder to regulator / hose assembly.   
Properly tighten the regulator’s hand wheel and connection device to tank 
 valve. Do not use tools.  
 
First check for leaks: 
Be sure the fittings at the end of the feed line going into the burner head and 
other end of the fuel feed line where the hose is attached are tight.  
Leak test with a soapy solution by mixing one part liquid soap solution with two 
parts water only. Do not use flame! 
 
1. Turn the Control Knob to the “OFF” position. Open the LP cylinder valve.  
2. Apply a soapy solution to these connections.  Bubbles will form if the 
connection is leaking. You will need to reconnect and leak test again. Upon 
completion of the leak test, turn off the LP cylinder valve and disconnect and 
remove the cylinder.  Go to the next step. 
 
Step 9.
  Tilt the heater over to a proper 
position (or using one of the shipping 
Styrofoam inserts to prop up the top half 
of the heater).  Secure the reflector  
onto Emitter by using the three Hex- 
Nuts, Flat washers and Lock washers.   
Make sure that the nuts are tight properly.  
 Stand the heater upright.  As shown in 
 Figure 8.                                                                           (Figure 8) 
 
Step 10.
 The cylinder Must be secured in the base and chained in the upright  position to 
keep it from falling or being knocked over. 
 
2. Installation 
 
This heater is intended for use outdoors only!  Don’t be used on any moving   
 objects and any enclosed areas! 
       
2.1 Installation warning 
 
The installation must conform with local, state and federal codes. In 
absents of such codes, install in accordance with the current American 
National Standard (ANSI) / National Fire Protection Association (NFPA) 
publication “ Standard for the Storage and Handling of Liquefied Petroleum 
Gases” ANSI / NFPA 58-Latest Revision, and “ National Fuel Gas Code” 
ANSOZ223.1.