Juniper Networks T1600 Benutzerhandbuch

Seite von 56
Figure 6: Typical DC Source Cabling to the T1600 Routing Node
Provisioning Additional Power for the T1600 Routing Node
For a maximally configured T1600 routing node, we recommend that you provision
at least 64 A @ –48 VDC for each power supply input in the system.
We recommend that you provision a facility circuit breaker for each DC power supply
input rated for at least 125% of the continuous current that the input draws at
–48 VDC.
Replacing the Rear Fan Tray
NOTE: If the rear fan tray (model number FAN-REAR-TX-T640-S) is already installed,
replacing the rear fan tray is not necessary. Proceed to “Upgrading the DC Power
Supplies” on page 17.
The rear fan tray is hot-insertable and hot-removable. To replace a fan tray, use the
following procedures:
Replacing the Rear Fan Tray
13
Replacing the Rear Fan Tray