Juniper Networks T1600 Benutzerhandbuch

Seite von 56
user@host# exit
Tools Required
To upgrade the SIBs, you need the following tools and parts.
Electrostatic discharge (ESD) grounding wrist strap
Phillips (+) screwdrivers, numbers 1 and 2
Removing a Standard SIB or SIB Version B
To remove a standard SIB or SIB version B, follow this procedure:
1.
2.
Take the SIB offline by using one of the following methods:
Press and hold the 
ONLINE/OFFLINE
 button on the SIB faceplate for about
five seconds until the 
OK
 LED is not lit.
Issue the 
request chassis sib offline
 command. For example:
user@host> request chassis sib offline slot 0
NOTE: When you bring an active SIB offline, the spare SIB becomes active and
transitions to the 
Online
 state.
3.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the
ejector handles on each side of the SIB faceplate.
4.
Flip the ejector handles outward to unseat the SIB.
5.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of
the way out of the chassis.
6.
Place one hand underneath the SIB to support it and slide it completely out of
the chassis. Place the SIB on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove
them. Place each component on an antistatic mat resting on a stable, flat surface.
30
Upgrading SIBs
T1600 Routing Node Upgrade Guide