Juniper Networks T1600 Benutzerhandbuch

Seite von 56
Verifying the Installation of a T1600-SIB
To verify that the T1600-SIB is functioning normally, follow this procedure:
1.
Check the LEDs on the T1600-SIB faceplate.
The green 
OK
 LED should light steadily a few minutes after the T1600-SIB
is installed.
If the 
FAIL
 LED is lit steadily, remove and install the T1600-SIB again. Make
sure that the T1600-SIB is seated properly. If the 
FAIL
 LED still lights steadily,
the T1600-SIB is not functioning properly. Contact your customer support
representative.
2.
Verify that four T1600-SIB are in the 
Online
 state and one SIB is in the 
Spare
state. Display the status of the T1600-SIB by issuing the 
show chassis sibs
command:
user@host> show chassis sibs
 Slot  State               Uptime
 0    Spare            0 days, 30 minutes, 12 seconds
 1    Online           0 days, 25 minutes, 45 seconds
 2    Online           0 days, 20 minutes, 28 seconds
 3    Online           0 days, 15 minutes, 7 seconds
 4    Online           0 days, 10 minutes, 52 seconds
To bring a T1600-SIB online, issue the 
request chassis sib online
 operational
mode command.
Preparing to Exit Upgrade Mode
After all five T1600-SIBs have been installed, use the following commands to exit
upgrade mode :
1.
Determine if GRES is enabled.
user@host> show system switchover
Graceful switchover: On
Configuration database: Ready
Kernel database: Ready
2.
Verify that the Routing Engines are operating properly by issuing the 
show chassis
routing-engine
 command.
user@host> show chassis routing-engine
Routing Engine status:
  Slot 0:
    Current state                  Master
    Election priority              Master (default)
    Temperature                 32 degrees C / 89 degrees F
    CPU temperature             33 degrees C / 91 degrees F
Upgrading SIBs
33
Upgrading SIBs