The goal of the WallPlate site survey is to
determine the average RSSI loss through one
room/wall combination
Provisioning the WallPlates
• Order the number of WallPlates according to the RSSI loss through one room/wall. If the
floor material is the same as the walls e.g. concrete, then the vertical loss will be similar
(usually +3dB to +6dB). Offset the installation with each floor so that WallPlates are not
stacked vertically above one another.
(usually +3dB to +6dB). Offset the installation with each floor so that WallPlates are not
stacked vertically above one another.
• Order 5% extra WallPlates for coverage in non-standard areas of the hotel; such as
rooms blocked by an elevator shaft. During the installation, if coverage holes exist, plug
the hole by installing an extra WallPlate.
the hole by installing an extra WallPlate.
Once the typical RSSI loss through a hotel is determined, site surveys at similar hotels become
unnecessary as the same plan can be used repeatedly.
unnecessary as the same plan can be used repeatedly.
WallPlate Density Chart
Based on the RSSI loss from one room/wall, order the indicated number of WallPlates, plus 5%
margin.
RSSI loss is…
margin.
RSSI loss is…
Horizontal WP density
Vertical WP offset
>30dB
One every three rooms
Install offset one room
>20dB and <30dB
One every four rooms
Install offset two rooms
>10dB and <20dB
One every four to six rooms
Install offset three rooms
<10dB
One every eight rooms
Install offset four rooms