The goal of the WallPlate site survey is to 
determine the average RSSI loss through one 
room/wall combination 
 
 
Provisioning the WallPlates 
•  Order the number of WallPlates according to the RSSI loss through one room/wall.  If the 
floor material is the same as the walls e.g. concrete, then the vertical loss will be similar 
(usually +3dB to +6dB).  Offset the installation with each floor so that WallPlates are not 
stacked vertically above one another. 
•  Order 5% extra WallPlates for coverage in non-standard areas of the hotel; such as 
rooms blocked by an elevator shaft.  During the installation, if coverage holes exist, plug 
the hole by installing an extra WallPlate. 
Once the typical RSSI loss through a hotel is determined, site surveys at similar hotels become 
unnecessary as the same plan can be used repeatedly. 
WallPlate Density Chart 
Based on the RSSI loss from one room/wall, order the indicated number of WallPlates, plus 5% 
margin. 
 
RSSI loss is… 
Horizontal WP density 
Vertical WP offset 
>30dB 
One every three rooms 
Install offset one room 
>20dB and <30dB 
One every four rooms 
Install offset two rooms 
>10dB and <20dB 
One every four to six rooms 
Install offset three rooms 
<10dB 
One every eight rooms 
Install offset four rooms 
 