IBM Partner Pavilion Vitrual Switch Extension BMD00082 Benutzerhandbuch

Seite von 166
SmartConnect User’s Guide
114  
„
  Chapter 9: Switch Policies
BMD00082, February 2009
ServerMobility
The ServerMobility feature uses the DHCP Relay Agent information option (option 82) to sup-
port fixed server address allocation, based on host location. The Relay Agent information 
option allows the switch to append location information to packets sent to a DHCP server, as 
follows: 
„
Agent circuit ID sub-option encodes the chassis ID, in hexadecimal format. 
In the advanced management system, the chassis ID is displayed in the UUID field on the 
System Vital Product Data window (Monitors > Hardware VPD). The following exam-
ple shows how the chassis ID is configured in the Agent circuit ID sub-option: 
4F:B2:F3:A8:6E:34:35:54:8B:0B:D8:2D:F2:B7:E9:49
„
Agent remote ID sub-option encodes the switch slot number and the port ID that corre-
sponds to the blade server, in hexadecimal. The following example shows how Slot ID 1 
and Port Number 2 is configured in the Agent remote ID sub-option: 
01:0:0:0:02
VSE SmartConnect software provides the following ServerMobility configuration windows:
„
„