IBM Partner Pavilion Vitrual Switch Extension BMD00082 Benutzerhandbuch

Seite von 166
SmartConnect User’s Guide
BMD00082, February 2009
Chapter 9: Switch Policies  
„
  115
ServerMobility General Configuration
Use this window to configure global settings for the ServerMobility feature. 
Table 9-9  
ServerMobility - General Configuration Fields
Field
Description
Server Mobility State
Enables or disables the ServerMobility feature on the
VSE SmartConnect software. 
Relay on Non-Server-
Mobility Ports
Enables or disables BOOTP Relay for all ports that have 
ServerMobility disabled. 
Server Mobility Scheme
Selects the scheme to be used for encoding the option 82 information in 
the DHCP request packets, as follows: 
„
Switch: The switch name is encoded in the agent circuit ID sub-
option. 
„
Chassis: The chassis ID is encoded as the agent circuit ID sub-
option. 
„
Vmac: The virtual MAC address of the server blade port is encoded 
in the agent circuit ID sub-option.
Auto-Recovery State
Enables or disables DHCP failover for the ServerMobility ports. When 
enabled, a backup blade server will get the same IP address as the active 
blade server if and when the active blade server goes down.
Auto_Recovery Failover 
Time
Sets the lease time for the temporary IP address assigned by the switch 
to a backup (standby) blade server while the active blade server is up.
Set Server Mobility configu-
ration to factory default
Resets ServerMobility feature parameters to factory default values.