IBM Partner Pavilion DS4100 Benutzerhandbuch

Seite von 180
Clustering
 
support
 
Clustering
 
is
 
a
 
means
 
of
 
sharing
 
array
 
groups
 
among
 
controllers
 
to
 
provide
 
redundancy
 
of
 
controllers
 
and
 
servers.
 
This
 
redundancy
 
is
 
important
 
if
 
a
 
hardware
 
component
 
fails.
 
If
 
a
 
hardware
 
component
 
failure
 
occurs
 
in
 
a
 
cluster,
 
another
 
server
 
takes
 
ownership
 
of
 
the
 
array
 
group.
 
Clustering
 
requires
 
software
 
specific
 
to
 
your
 
operating
 
system.
 
For
 
more
 
information
 
about
 
clustering,
 
go
 
to
 
the
 
following
 
Web
 
site:
 
Inventory
 
checklist
 
After
 
you
 
unpack
 
the
 
DS4100
 
storage
 
server,
 
verify
 
that
 
you
 
have
 
the
 
following
 
items:
 
v
   
Hardware
 
   
Up
 
to
 
14
 
hard
 
disk
 
drives
 
(shipped
 
installed
 
in
 
the
 
DS4100)
Note:
  
The
 
DS4100
 
base
 
storage
 
server
 
is
 
shipped
 
with
 
no
 
SATA
 
hard
 
disk
 
drives
 
as
 
standard.
 
You
 
can
 
order
 
the
 
unit
 
with
 
up
 
to
 
14
 
250
 
GB
 
SATA
 
drive
 
CRUs
 
installed
 
at
 
the
 
factory.
 
The
 
DS4100
 
single-controller
 
storage
 
server
 
is
 
shipped
 
with
 
three
 
250
 
GB
 
SATA
 
drive
 
CRUs
 
as
 
standard.
 
You
 
can
 
order
 
the
 
unit
 
with
 
up
 
to
 
11
 
additional
 
SATA
 
drive
 
CRUs
 
installed
 
at
 
the
 
factory.
 
   
RAID
 
controllers
 
(shipped
 
installed
 
in
 
the
 
DS4100)
 
-
   
2
 
controllers
 
on
 
the
 
base
 
storage
 
server
 
-
   
1
 
controller
 
on
 
the
 
single-controller
 
storage
 
server
Note:
  
A
 
blank
 
controller
 
tray
 
is
 
installed
 
in
 
the
 
empty
 
controller
 
slot
 
in
 
the
 
DS4100
 
single-controller
 
storage
 
server
 
chassis.
 
For
 
proper
 
cooling
 
and
 
EMI
 
shielding,
 
do
 
not
 
remove
 
this
 
blank
 
controller
 
tray.
   
Two
 
fan
 
units
 
(shipped
 
installed
 
in
 
the
 
DS4100)
 
   
Power
 
supplies
 
(shipped
 
installed
 
in
 
the
 
DS4100)
 
-
   
2
 
power
 
supplies
 
on
 
the
 
base
 
storage
 
server
 
-
   
1
 
power
 
supply
 
on
 
the
 
single-controller
 
storage
 
server
Note:
  
A
 
blank
 
power
 
supply
 
tray
 
is
 
installed
 
in
 
the
 
empty
 
power
 
supply
 
slot
 
in
 
the
 
DS4100
 
single-controller
 
storage
 
server
 
chassis.
 
For
 
proper
 
cooling
 
and
 
EMI
 
shielding,
 
do
 
not
 
remove
 
this
 
blank
 
power
 
supply
 
tray.
   
Line
 
cord
 
jumpers
 
-
   
2
 
line
 
cord
 
jumpers
 
on
 
the
 
base
 
storage
 
server
 
-
   
1
 
line
 
cord
 
jumper
 
on
 
the
 
single-controller
 
storage
 
server
 
Line
 
cord
 
jumpers
 
are
 
power
 
cords
 
used
 
to
 
connect
 
the
 
DS4100
 
power
 
supply
 
units
 
to
 
the
 
IBM-certified
 
rack
 
power
 
distribution
 
units
 
(PDUs).
 
   
One
 
rack-mounting
 
hardware
 
kit,
 
including:
 
-
   
Two
 
rails
 
(right
 
and
 
left
 
assembly)
 
-
   
Eight
 
M6
 
black
 
hex-head
 
slotted
 
screws
 
-
   
Eight
 
M6
 
cage
 
nuts
 
-
   
Eight
 
M6
 
clip
 
nuts
   
Up
 
to
 
14
 
blank
 
drive
 
trays
 
(shipped
 
installed
 
in
 
the
 
DS4100)
 
 
 
Chapter
 
1.
 
Introduction
 
5