IBM Partner Pavilion DS4100 Benutzerhandbuch

Seite von 180
the
 
DS4000
 
storage
 
expansion
 
units
 
attached
 
to
 
the
 
DS4100
 
storage
 
server
 
should
 
be
 
plugged
 
into
 
the
 
same
 
two
 
independent
 
external
 
power
 
circuits
 
as
 
the
 
DS4100.
 
This
 
ensures
 
that
 
the
 
DS4100
 
storage
 
server
 
and
 
all
 
its
 
attached
 
storage
 
expansion
 
units
 
will
 
have
 
power
 
if
 
only
 
one
 
power
 
circuit
 
is
 
available.
 
In
 
addition,
 
having
 
all
 
the
 
right
 
or
 
all
 
the
 
left
 
power
 
supplies
 
plug
 
into
 
the
 
same
 
power
 
circuit
 
enables
 
the
 
components
 
in
 
the
 
storage
 
subsystem
 
to
 
power
 
on
 
simultaneously
 
during
 
an
 
unattended
 
restoration
 
of
 
power.
 
See
 
for
 
an
 
example
 
of
 
redundant
 
power
 
connections.
Note:
  
This
 
guideline
 
cannot
 
be
 
followed
 
for
 
the
 
DS4100
 
single-controller
 
storage
 
server,
 
which
 
does
 
not
 
offer
 
redundant
 
power
 
supplies.
 
However,
 
you
 
can
 
use
 
Uninterruptible
 
Power
 
Supply
 
(UPS)
 
units
 
with
 
the
 
DS4100
 
single-controller
 
storage
 
server
 
to
 
provide
 
protection
 
against
 
power
 
brown-outs
 
and
 
short
 
power
 
outages.
 
v
   
Before
 
any
 
planned
 
system
 
shutdown
 
or
 
after
 
any
 
system
 
additions,
 
removals,
 
or
 
modifications
 
(including
 
logical
 
drive
 
creations,
 
storage
 
partitioning
 
definitions,
 
hardware
 
changes,
 
and
 
so
 
on),
 
save
 
the
 
storage
 
subsystem
 
profile
 
as
 
explained
 
in
 
the
 
DS4000
 
Storage
 
Manager
 
guide
 
for
 
your
 
operating
 
system.
 
Save
 
the
 
profile
 
in
 
a
 
location
 
other
 
than
 
the
 
logical
 
drives
 
created
 
for
 
the
 
DS4100
 
storage
 
server.
 
v
   
Ensure
 
that
 
your
 
system
 
is
 
in
 
an
 
optimal
 
state
 
before
 
you
 
shut
 
it
 
down.
 
Never
 
turn
 
the
 
power
 
off
 
if
 
any
 
fault
 
light
 
is
 
lit;
 
be
 
sure
 
to
 
resolve
 
any
 
error
 
conditions
 
before
 
you
 
shut
 
down
 
the
 
system.
 
v
   
During
 
any
 
maintenance
 
or
 
attended
 
power-up
 
procedure,
 
carefully
 
follow
 
the
 
power-up
 
sequence
 
listed
 
in
 
Check
 
that
 
each
 
component
 
of
 
the
 
subsystem
 
is
 
powered-on
 
in
 
the
 
proper
 
order
 
during
 
this
 
entire
 
power-up
 
procedure
 
to
 
ensure
 
the
 
controller
 
will
 
be
 
able
 
to
 
optimally
 
access
 
all
 
of
 
your
 
storage
 
subsystems.
 
v
   
The
 
storage
 
subsystem
 
supports
 
simultaneous
 
power-up
 
to
 
the
 
system
 
components;
 
however,
 
you
 
should
 
always
 
follow
 
the
 
power-up
 
sequence
 
listed
 
in
 
during
 
any
 
attended
 
power-up
 
procedure.
 
v
   
A
 
storage
 
system
 
in
 
an
 
optimal
 
state
 
should
 
recover
 
automatically
 
from
 
an
 
unexpected
 
shutdown
 
and
 
unattended
 
simultaneous
 
restoration
 
of
 
power
 
to
 
system
 
components.
 
After
 
power
 
is
 
restored,
 
call
 
IBM
 
support
 
if
 
any
 
of
 
the
 
following
 
conditions
 
occur:
 
   
The
 
storage
 
subsystem
 
logical
 
drives
 
and
 
arrays
 
are
 
not
 
displayed
 
in
 
the
 
DS4000
 
Storage
 
Manager
 
graphical
 
user
 
interface
 
(GUI).
 
   
The
 
storage
 
subsystem
 
logical
 
drives
 
and
 
arrays
 
do
 
not
 
come
 
online.
 
   
The
 
storage
 
subsystem
 
logical
 
drives
 
and
 
arrays
 
seem
 
to
 
be
 
degraded.
Storage
 
server
 
components
 
The
 
following
 
sections
 
show
 
the
 
components
 
of
 
the
 
DS4100
 
storage
 
server.
 
Hot-swappable
 
devices
 
enable
 
you
 
to
 
maintain
 
the
 
availability
 
of
 
your
 
system
 
while
 
you
 
remove,
 
install,
 
or
 
replace
 
a
 
hot-swap
 
device.
 
All
 
DS4100
 
storage
 
server
 
models
 
support
 
hot-swap
 
SATA
 
hard
 
disk
 
drives
 
and
 
cooling
 
fan
 
CRUs,
 
so
 
you
 
can
 
remove
 
and
 
replace
 
these
 
components
 
without
 
turning
 
off
 
the
 
storage
 
server.
 
In
 
addition,
 
the
 
DS4100
 
base
 
storage
 
server
 
supports
 
hot-swap
 
RAID
 
controllers
 
and
 
power
 
supplies.
 
 
 
Chapter
 
1.
 
Introduction
 
7