IBM Partner Pavilion DS4100 Benutzerhandbuch

Seite von 180
Attention:
  
The
 
DS4100
 
single-controller
 
storage
 
server
 
does
 
not
 
support
 
hot-swap
 
RAID
 
controllers
 
or
 
power
 
supplies.
 
You
 
will
 
lose
 
access
 
to
 
data
 
if
 
you
 
attempt
 
to
 
remove
 
or
 
replace
 
a
 
functioning
 
(non-failed)
 
RAID
 
controller
 
or
 
power
 
supply
 
in
 
a
 
DS4100
 
single-controller
 
storage
 
server
 
without
 
first
 
powering
 
down
 
the
 
storage
 
server.
 
Hot-swap
 
drive
 
bays
 
The
 
hot-swap
 
drive
 
bays
 
that
 
are
 
accessible
 
from
 
the
 
front
 
of
 
your
 
storage
 
server
 
are
 
shown
 
in
 
 
 
 
The
 
DS4100
 
supports
 
up
 
to
 
14
 
DS4000
 
1.5
 
Gbps
 
SATA
 
hard
 
disk
 
drives.
 
These
 
drives
 
are
 
preinstalled
 
in
 
drive
 
trays.
 
The
 
unit
 
consisting
 
of
 
the
 
drive
 
and
 
the
 
drive
 
carrier
 
assembly
 
is
 
called
 
a
 
drive
 
CRU.
 
The
 
SATA
 
drive
 
CRU
 
includes
 
the
 
drive
 
tray,
 
the
 
SATA
 
drive,
 
and
 
the
 
hard
 
disk
 
drive
 
(HDD)
 
interposer
 
card.
 
You
 
install
 
the
 
drive
 
CRUs
 
in
 
the
 
14
 
drive
 
bays
 
on
 
the
 
front
 
of
 
the
 
storage
 
server.
 
There
 
are
 
no
 
serviceable
 
parts
 
in
 
a
 
drive
 
CRU.
 
If
 
it
 
fails,
 
it
 
must
 
be
 
replaced
 
in
 
its
 
entirety
 
(drive,
 
interposer,
 
bezel,
 
and
 
tray).
 
 
Attention:
   
1.
   
Never
 
hot-swap
 
a
 
drive
 
CRU
 
when
 
its
 
associated
 
green
 
Activity
 
LED
 
is
 
flashing.
 
Hot-swap
 
a
 
drive
 
CRU
 
only
 
when
 
its
 
associated
 
amber
 
Fault
 
LED
 
lights
 
and
 
is
 
not
 
flashing
 
or
 
when
 
the
 
drive
 
is
 
inactive
 
and
 
its
 
associated
 
green
 
Activity
 
LED
 
lights
 
and
 
is
 
not
 
flashing.
 
2.
   
The
 
SATA
 
drive
 
and
 
its
 
HDD
 
card
 
are
 
digitally
 
signed
 
together
 
at
 
the
 
factory.
 
Do
 
not
 
swap
 
drives
 
and
 
interposers
 
between
 
drive
 
CRUs.
 
Do
 
not
 
replace
 
one
 
SATA
 
drive
 
with
 
another
 
SATA
 
drive.
 
These
 
actions
 
will
 
result
 
in
 
a
 
drive
 
CRU
 
that
 
cannot
 
be
 
recognized
 
by
 
the
 
storage
 
server
 
RAID
 
controller.
 
3.
   
After
 
you
 
remove
 
a
 
drive
 
CRU,
 
wait
 
at
 
least
 
70
 
seconds
 
before
 
replacing
 
or
 
reseating
 
the
 
drive
 
CRU
 
to
 
allow
 
the
 
drive
 
to
 
properly
 
spin
 
down.
 
Failure
 
to
 
do
 
so
 
may
 
cause
 
undesired
 
events.
Note:
  
If
 
the
 
hard
 
disk
 
drive
 
you
 
want
 
to
 
remove
 
is
 
not
 
in
 
a
 
failed
 
or
 
bypass
 
state,
 
always
 
use
 
the
 
DS4000
 
Storage
 
Manager
 
client
 
program
 
either
 
to
 
place
 
the
 
drive
 
in
 
a
 
failed
 
state
 
or
 
to
 
place
 
the
 
array
 
that
 
is
 
associated
 
with
 
the
 
drive
 
(or
 
drives)
 
in
 
an
 
offline
 
state
 
before
 
you
 
remove
 
the
 
drive
 
from
 
the
 
enclosure.
 
Front
 
controls
 
and
 
indicators
 
This
 
section
 
describes
 
the
 
primary
 
controls
 
on
 
the
 
front
 
of
 
the
 
storage
 
server.
 
The
 
locations
 
of
 
these
 
primary
 
controls
 
are
 
shown
 
in
 
 
 
Hot-swap drive bays
f10ug052
  
Figure
 
2.
 
DS4100
 
hot-swap
 
drive
 
bays
 
 
8
 
IBM
 
TotalStorage
 
DS4100
 
Storage
 
Server:
 
Installation,
 
User’s,
 
and
 
Maintenance
 
Guide