3. Controls and Adjustments
a) Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch
Dip Switch No.
1

3
4
5
6
7
8
9
10
KMS-1400MLH
OFF OFF OFF ON ON ON ON OFF OFF ON
S5 Dip Switch (Do Not Adjust)
Dip Switch No.
1

3
4
5
KMS-1400MLH
OFF ON OFF OFF OFF
b) Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts counting when the thermistor reads 48°F (9°C) at the evaporator 
outlet. No adjustment is required under normal use, as the harvest timer is adjusted to 
the suitable position. Before changing this setting, contact Hoshizaki Technical Support 
at 1-800-33-1940 for recommendations. Keep in mind that setting the harvest timer to a 
longer setting will decrease 4 hour production.
Dip Switch Setting
Time (seconds)
No. 1
No. 
OFF
OFF
60
ON
OFF
90
OFF
ON
10
ON
ON
180
S4 Dip Switch
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & )
Normally off (8)
Do not adjust (7)