Fig. 2
Bin Control
Bin Control 
Switch Closed
(calling for ice)
Bin Control
Switch Open
(bin full)
F. Bin Control
This machine uses a lever-actuated proximity switch (mechanical bin control) to control 
the ice level in the storage bin. No adjustment is required.
1. Explanation of Operation
The bin control is connected to the red K4 connector on the control board. When the 
bin control is calling for ice (proximity switch closed; green LED, BC CLOSED, on), the 
control board continues icemaking operations. When the bin control is activated in the 
bin full position (proximity switch open; yellow LED, BC OPEN, on), the control board 
shuts down the unit. However, to prevent incomplete batches of ice from forming on the 
evaporator, the control board will only shut down the machine within the first 5 minutes of 
the freeze cycle. If ice pushes the lever in after the first five minutes of the freeze cycle, 
the control board will allow the machine to complete the freeze cycle and the following 
harvest cycle before shutting down the machine.
2. Bin Control Check Procedure 
1) Clear any ice away from the bin control.
) Turn the control switch to "ICE".
3) Check that the green "BC CLOSED" LED on the control board is on.
4) Activate the bin control actuator (press the actuator in). Check that the yellow "BC 
OPEN" LED on the control board is on.
5) Disconnect the red K4 bin control connector from the control board.
6) Check for continuity across the bin control leads. When calling for ice, the bin control 
proximity switch should be closed. If open, replace the bin control. Activate the bin 
control actuator (press the actuator in), check for continuity across the bin control leads. 
The bin control proximity switch should be open. If closed, replace the bin control. 
7) Reconnect the red K4 connector. Allow the machine to cycle into the freeze cycle. 
In the first 5 minutes of the freeze cycle, activate the bin control actuator (press the 
actuator in). The yellow "BC OPEN" LED should come on and the machine should turn 
off. If not, replace the control board.