Honeywell ADEMCO LYNXR Series Installationsanleitung

Seite von 72
  
 
–55– 
System Communication 
 
Report  
3+1/4+1 Standard  
3+1/4+1 Expanded 
4+2 
Alarm  
SSS(S) A 
SSS(S) A 
AAA(A) Z 
SSSS AZ  
Trouble 
SSS(S) T 
SSS(S) T 
TTT(T) t 
SSSS Tt 
Bypass 
SSS(S) B 
SSS(S) B  
BBB(B) b 
SSSS Bb  
AC Loss 
SSS(S) E 
SSS(S) E  
EEE(E) AC 
SSSS EAC  
Low Battery 
SSS(S) L 
SSS(S) L  
LLL(L) LB 
SSSS LLB  
Open  
SSS(S) O  
SSS(S) O  
OOO(O) U 
SSSS OU  
Close 
SSS(S) C 
SSS(S) C 
CCC(R) U 
SSSS CU 
Test 
SSS(S) G 
SSS(S) G 
GGG(G)g 
SSSS Gg 
Restore Alarm 
SSS(S) R 
SSS(S) R  
RRR(R) Z 
SSSS RZ 
AC Restore  
SSS(S) RA SSS(S) 
RA 
RARARA(RA)Ac 
SSSSRA Ac 
Low Battery Restore 
SSS(S) RL SSS(S) 
RL  
RLRLRL(RL)LB 
SSSS RLLB 
Trouble Restore 
SSS(S) RT SSS(S) 
RT  
RTRTRT (RT)t 
SSSS RTt  
Bypass Restore 
SSS(S) RB 
SSS(S) RB 
RBRBRB (RB)b 
SSSS RBb  
 
ADEMCO Contact ID® Reporting takes the following format: CCCC Q EEE GG ZZZ where: 
CCCC =   Customer (subscriber) ID 
Q = 
  Event qualifier, where: E = new event, and R = restore 
EEE =    Event code (3 hex digits) (for a complete list of event codes, refer to the central office receiver manual) 
GG = 
  Always “00” 
ZZZ = 
 Zone/Contact ID® number reporting the alarm, or user number for open/close reports. System 
 status messages (AC Loss, Walk Test, etc.) contain zeroes in the ZZZ location. 
 
 
CONTACT ID® EVENT CODES
Code 
Definition 
110 Fire 
Alarm 
121 Duress 
122 
Alarm, 24-hour Silent 
123 
Alarm, 24-hour Audible  
131 Alarm, 
Perimeter 
132 Alarm, 
Interior 
134 Alarm, 
Entry/Exit 
135 Alarm, 
Day/Night 
145 
Wireless Dialer Tamper (plus Zone 93) (Alarm) 
146 Silent 
Burglary 
150 
Alarm, 24-Hour Auxiliary 
301 AC 
Power 
338 
Wireless Dialer Low Battery (plus Zone 93) 
341 
Wireless Dialer Tamper (plus Zone 93)  (Trouble) 
342* 
Wireless Dialer AC Loss (plus Zone 93)  
344 
RF Jam Detected 
351* 
Wireless Dialer Phone Line Cut (plus Zone 93) 
354 
Fail to Report 
355 
Wireless Dialer Loss of RF Supervision 
(plus Zone 93) 
355 
(Zone 000) Reported by the 5842 Wireless Dialer 
373 
Fire Loop Trouble 
374 
Exit Error Alarm 
*If supported by the 5842 Wireless Dialer that is installed.
 
Code 
Definition 
380 
Global Trouble, Trouble Day/Night 
381 
RF Supervision Trouble 
383 
RF Sensor Tamper  (Trouble) 
384 
RF Sensor Low Battery 
401 
Disarmed, Armed AWAY (NO DELAY),  
Armed AWAY 
403 
Scheduled Auto Arm 
406 Cancel 
by 
User 
407 
Remote Arm/Disarm (Downloading) 
408 
Quick Arm AWAY/NO DELAY 
441 
Disarmed/Armed STAY/NO DELAY, Quick Arm 
STAY/NO DELAY 
570 Bypass 
602 Periodic 
Test 
606 
AAV to follow 
607 System 
Test 
623 
Event Log 80% Full 
654 System 
Inactivity 
NOTE:  The following codes are logged in the event log upon 
occurrence, but are not reported: 
305 = System Reset 
627 = Keypad Program Mode Entry