Honeywell ADEMCO LYNXR Series Installationsanleitung

Seite von 72
 
 
–56– 
Troubleshooting Guide 
 
S Y S T E M   ( i n c l u d i n g   W i r e l e s s )  
SYMPTOM 
POSSIBLE CAUSE 
REMEDY 
1. Transmitter 
signal 
not received at 
control. 
1a.  Transmitter not properly powered. 
1b.  If Transmitter is 5827, House Code not 
set in field 
✻24, or transmitter is not set 
to same House Code set in that field.
 
1c.  Transmitter is located too far from RF 
receiver. 
1d.  There is metal shielding between 
transmitter and RF receiver. 
1e. Transmitter 
is 
malfunctioning. 
 
1f.  Transmitter No. (zone) is not 
programmed. 
1a  Check or change transmitter's battery.  
1b.  Check code switches inside transmitter. 
Must match with RF House Code 
programmed. 
 
1c.  Move transmitter or RF receiver. 
1d.  Check for large metal obstructions, then 
relocate transmitter if necessary. 
1e. Verify by activating control with 
another, similar transmitter. If O.K. 
now, return defective transmitter. 
1f. Verify 
programming. 
2. Transmitter 
zone 
number appears 
during Transmitter 
Sniffer mode, but 
does not clear. 
2a.  Transmitter zone type (ZT) is set to 00 
(Not Used). 
2b.  Transmitter battery not installed. 
2c.  5800 System transmitter not "entered" in 
system.  
2a.  Set ZT to a valid active zone type in 
field 
✻56. 
 
2b.  Install proper battery. 
2c.  "Enter" unit in field 
✻56 or ✻83. 
 
3. Low 
battery 
message 
on keypad. 
3a.  "Low Bat" (no zone Nos.) 
 3b.  "Low Bat" + "00". 
 3c.  "Low Bat" + "nn". 
 
 
3a.  System battery is low or missing. 
3b.  Remote RF keypad/button battery is low. 
3c.  Transmitter for zone “nn” has a low 
battery. 
 
 
3a.  Replace system battery. 
3b.  Replace battery in the RF keypad. 
3c.  Replace the battery in the displayed 
transmitter. 
4. 
Periodic beep(s) from 
keypad.
 
4a.  System is in Test mode. 
4b.  A transmitter low battery has occurred 
and is displayed. 
 
4c.  A supervision fault has occurred. 
 
4d.  System low battery 
4a.  Enter Code + OFF to exit Test mode. 
4b.  Enter Code + OFF and replace the 
battery. 
 
4c.  Check the transmitter indicated. 
Restore communication to the receiver 
to cancel the condition. 
4d.  Replace system battery 
5. 
With 5800 System, 
there is no response 
to a transmitter in 
normal operation, 
although zone 
number clears during 
Transmitter Sniffer 
mode.
 
Put control in Test mode. If zone does not 
respond, try operating the tamper switch or 
another input to the transmitter. 
5a.  If another input causes the zone to be 
displayed, the wrong input was "entered" 
when programming. 
5b.  If no response at all from this 
transmitter, this physical transmitter 
has not been entered by the system. 
Transmitter Sniffer display is being 
cleared by another unit programmed for 
this zone. 
 
 
 
5a.  Delete input's serial number (not the 
zone), and enter the proper input (see 
field 
✻56). 
 
5b.  Determine which transmitter is 
programmed for this zone and 
reprogram as necessary. 
6. 
Nuisance or phantom 
alarm. 
6a.  Sensors not properly installed, wired, or 
monitored. 
6b.  Universal transmitter (5817) 
programmed wrong. 
6a.  Check installation to see if in 
accordance with established procedure. 
6b.  Check programming switches on 
transmitter. 
7. 
Intrusion alarm for 
no apparent reason. 
7a.  Protected door or window opened while 
system armed. 
7b.  Improper user operation of exit/entry 
delays. 
7c.  Magnets located too far from switches, 
and/or doors and windows not properly 
aligned.  
7a.  Check with all occupants of protected 
home. 
 
7b.  Check setting of entry and exit delays. 
7c.  Check all openings for proper switch 
and magnet orientation.