Fuel System Specifications and Recommendations (LP) Liquid Propane
Natural Gas (N)
Gas Volume and Pressure
The dryer is designed to operate on natural gas having a heat value of approximately 1000 BTU per 
cubic foot. The dryer is equipped with a natural gas supply pipe system connected to the heater solenoid 
valves. A regulated pressure of 10 PSI must be provided at the connection to the dryer, with gas 
available in sufficient volume to maintain the operating pressure.
Figure 8B Grain dryer connected to a natural gas supply tank.
Dryer 
Model #
Maximum Heat
Capacity BTU Per Hour
Maximum Fuel Flow 
Gals Per Hour
Fuel Line Size*
Heater Orifice Drill Size
1108
3,000,000
33
1/2''
1/4''
1110
3,500,000
38
1/2''
9/32''
1112
4,500,000
49
1/2''
21/64''
1114
5,750,000
63
1/2''
11/32''
1116
5,750,000
63
1/2''
11/32''
1118
6,750,000
74
1/2''
3/8''
1120
7,500,000
82
1/2''
25/64''
1122
8,750,000
96
3/4''
7/16''
1126
10,250,000
112
3/4''
29/64''
1214
6,200,000
68
3/4''
(U)9/32'' (L)7/32''
1216
7,200,000
79
3/4''
(U)21/64'' (L)7/32''
1218
7,200,000
79
3/4''
(U)21/64'' (L)7/32''
1220
8,500,000
93
3/4''
(U)11/32'' (L)1/4''
1222
9,750,000
107
3/4''
(1)3/8'' (1)1/4''
1226
10,500,000
115
3/4''
(1)25/64'' (1)1/4''
1314
8,100,000
88
3/4''
(3)7/32''
1318
8,100,000
88
3/4''
(3)7/32''
1322
8,100,000
88
3/4''
(3)7/32''
160AB
3,000,000
33
1/2''
1/4''
210AB
3,500,000
33
1/2''
1/4''
300AB
4,500,000
49
1/2''
21/64''
375AB
5,500,000
60
1/2''
21/64''
400AB
5,500,000
60
1/2''
21/64''
415AB
7,000,000
66
1/2''
(2)9/32''
600AB
9,000,000
98
3/4''
(2)21/64''
* Maximum line size for a 100' distance.
 for required pressure and 
typical maximum fuel flow rates.
 for recommended 
line size.