GSI Outdoors PNEG-338 Benutzerhandbuch

Seite von 32
20
PNEG-338 Portable Dryer Installation Manual
8. Fuel Connection
Fuel System Specifications and Recommendations (N) Natural Gas
Figure 8C The fuel connection point is equipped with a
  Y-strainer and Maxon safety valve.
Dryer 
Model #
Maximum Heat 
Capacity BTU Per Hour
Maximum Fuel Flow 
Cubic Feet Per Hour
Fuel Line Size* (Dia.)
Heater Orifice Drill Size
1108
3,000,000
3,000
1-1/4'' 
3/8''
1110
3,500,000
3,500
1-1/4''
13/32''
1112
4,500,000
4,500
1-1/2'' 
1/2''
1114
5,750,000
5,750
1-1/2'' 33/64''
1116
5,750,000
5,750
1-1/2'' 
33/64''
1118
6,750,000
6,750
2'' 35/64''
1120
7,500,000
7,500
2'' 
37/64''
1122
8,750,000
8,750
2'' 19/32''
1126
10,250,000
10,250
2'' 
41/64''
1214
6,200,000
6,200
1-1/2'' (1)13/32'' 
(1)5/16''
1216
7,200,000
7,200
2'' 
(1)1/2'' (1)5/16''
1218
7,200,000
7,200
2'' (1)1/2'' 
(1)5/16''
1220
8,500,000
8,500
2'' 
(1)33/64'' (1)3/8''
1222
9,750,000
9,750
2'' (1)35/64'' 
(1)3/8''
1226
10,500,000
10,500
2'' 
(1)37/64'' (1)3/8''
1214S
6,000,000
6,000
1-1/2'' (2)3/8''
1218S
6,000,000
6.000
1-1/2'' 
(2)13/32''
1220S
9,000,000
9,000
2'' (2)1/2''
1222S
9,000,000
9,000
2'' 
(2)1/2''
1226S
13,500,000
13,500
2'' (2)17/32''
1314
8,100,000
8,100
2'' 
(3)5/16''
1318
8,100,000
8,100
2'' (3)5/16''
1322
8,100,000
8,100
2'' 
(3)5/16''
160AB
3,000,000
3,000
1-1/4'' 3/8''
210AB
3,500,000
3,500
1-1/4'' 
13/32''
300AB
4.500,000
4,500
1-1/2'' 1/2''
375AB
5,500,000
5,500
1-1/2'' 
33/64''
400AB
5,500,000
5,500
1-1/2'' 33/64''
415AB
7,000,000
7,000
2'' 
(2)13/32''
600AB
9,000,000
9,000
2'' (2)1/2''
* Maximum line size for a 100' distance.