Temperature and Dynamic Acceleration: 
(Figure 9)
 
a.  Socket A – Positive (+ RED) connection for the dynamic acceleration and 
with output on the BNC “J1” and the (2) pin Output connectors. 
b.  Socket B – Negative (- BLACK) connection for the dynamic acceleration 
and volt output for temperature. 
c.  Socket C – Positive (+ WHITE) connection for the voltage output for 
temperature with output on the BNC “J2”, only. 
d.  Socket D – Shield/Drain wire connection that is directed to “Earth” ground. 
 
 
 
 
 
 
 
Dual Vibration with 4-20mA output and Dynamic outputs: 
(Figure 9A)
 
a.  Socket A – Positive (+ WHITE) connection for the dynamic acceleration 
and would output on the BNC “J1” and the (2) pin MIL output connectors. 
b.  Socket B – Negative (- BLACK) connection for the dynamic acceleration 
and 4-20mA velocity output. 
c.  Socket C – Positive (+ RED) connection for the 4-20mA signal, and would 
output to the BNC “J2”, (not used in this application).This setup requires 
optional (12) position plug in block (CTC #JB905-2A) to wire LP series 
sensor to the PLC/DCS system. The PLC/DCS system then provides the 
power for the loop in this setup, using CTC’s LP series sensors. (Figure 
9A
d.  Socket D – Shield/Drain wire connection that is directed to “Earth” ground. 
 
PLEASE NOTE: In this application, the portable data acquisition system 
needs to have sensor power turned off before collecting data.
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 9. Connecting Cables to Switch Box 
For Vibration and Temperature 
Figure 9A. Optional Plug-in Block 
#JB905-2A for Vibration and 4-20mA 
*NOTE: 
WHITE “A” terminals not used 
Signal Wire Outputs 
Optional Plug-in Block 
CTC part # JB905-2A 
Sensor 
Wire 
Inputs 
White 
Black 
Red 
GRN