FieldServer Technologies Video Game Controller 1.1 Benutzerhandbuch
Ruinet Utility User Manual
Page 7 of 46
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com
2.2.1. FieldServer
Information – Settings Aspect
Parameter
Description
Tier
FieldServers have the ability to run as “multiple” FieldServers on
one platform. To differentiate between the different running
applications, each of the applications is referred to as a Tier with a
specific name.
one platform. To differentiate between the different running
applications, each of the applications is referred to as a Tier with a
specific name.
FieldServer_Name
A name by which a FieldServer is identified - need not be unique.
N1 IP Address
The IP address of the N1 Ethernet Adapter.
N1 Netmask
Netmask of N1 Ethernet Adapter.
N1 Gateway 1
The IP address of the gateway that N1 Ethernet messages use if
the destination IP is not found on the local network.
the destination IP is not found on the local network.
N2 IP Address
The IP address of the N2 Ethernet Adapter.
N2 Netmask
Netmask of N2 Ethernet Adapter.
N2 Gateway 1
The IP address of the gateway that N2 Ethernet messages use if
the destination IP is not found on the local network.
the destination IP is not found on the local network.
Cache_Age_Limit
Maximum age of data in a cache Map Descriptor for immediate
response to poll. Default 5 minutes. See Error! Reference source
not found.
response to poll. Default 5 minutes. See Error! Reference source
not found.
Cache_Time_To_Live
The time that the FieldServer maintains the port expanded polling in
Port Expander Mode. Default 5 minutes. See Configuration
Manual for more information.
Port Expander Mode. Default 5 minutes. See Configuration
Manual for more information.
Cache_Size
The maximum number of cache Map Descriptors allowed.
System_Node_ID
Use is driver dependent. Generally used to identify the FieldServer
as a node when it is configured as a server.
as a node when it is configured as a server.
Network_number
Displayed where a protocol requires the FieldServer to be assigned
a network number (e.g. BACnet).
a network number (e.g. BACnet).
Hot_Standby_Mode
Where specified, this parameter defines the behavior of the standby
FieldServer in Hot Standby mode. In Mode 1 the FieldServer is
completely passive; in Mode 2 the standby FieldServer polls the
connected devices through alternate communication paths. Refer
to the Configuration Manual for more information.
FieldServer in Hot Standby mode. In Mode 1 the FieldServer is
completely passive; in Mode 2 the standby FieldServer polls the
connected devices through alternate communication paths. Refer
to the Configuration Manual for more information.
Port_Expander_Mode
Indicates whether the port expander mode function is enabled or
not.
not.
Cache_Map_Descriptor_
Scan_Interval
Scan_Interval
Default is two seconds.
If the value 65535 is displayed, then this is an error and it indicates
that there is no setting.
If the value 65535 is displayed, then this is an error and it indicates
that there is no setting.
Hot_Standby_Designation
Primary or Secondary. On boot the primary tries to become the
active and the secondary tries to become the standby FieldServer.
This behavior may be different if the so called secondary
FieldServer gets re-booted first.
active and the secondary tries to become the standby FieldServer.
This behavior may be different if the so called secondary
FieldServer gets re-booted first.
Hot_Standby_Pair_Name
A name by which a pair of FieldServers configured as a Hot
Standby pair is known. When one of a pair boots, it broadcasts a
message with its pair name in order to try and locate the other
FieldServer that forms the hot standby pair.
Standby pair is known. When one of a pair boots, it broadcasts a
message with its pair name in order to try and locate the other
FieldServer that forms the hot standby pair.