Chief Personal Lift SL220 Benutzerhandbuch
SL220
Installation Instructions
16
RS485 Information
Communication parameters as specified in ANSI TIA/EIA-485-A:
Table 2: COMMAND STRINGS FOR SL-220
•
The serial control command string is set up as follows:
Table 3: SERIAL CONTROL COMMAND STRING
•
Product ID for the SL-220: 05
•
Address controlled by dip switch settings
•
Basic Commands available for the SL-220 in the factory-supplied configuration:
•
03: Cancel Move = 3E0500037D0D
•
10: Extend to End of Travel = 3E0500107B0D
•
12: Retract to End of Travel = 3E0500127D0D
•
Message Data = The data is required for the available commands:
•
03: None
•
10: None
•
12: None
•
Check Code is calculated.
Baud
Rate
Data
Length
Parity
Stop
Bit
Flow
Control
9600
8 Bits
None
1
None
Start of
Message
(HEX)
(HEX)
Product ID
(HEX)
Address
(HEX)
Command
(HEX)
Message Data
(HEX)
Check Code
(HEX)
End of
Message
(HEX)
(HEX)
3E
XX
XX
XX
XX
XX
0D