Fairchild CAM/CMOS-2K.LS Benutzerhandbuch

Seite von 42
LED 
This command allows you to change the color.  When selecting the option you need to, enter 
the appropriate single digit number and hit enter.  Your screen will be blank during this 
command 
You can input one of the following: 
 
 
 
 
Value          Function 
 
 
 
 
   0 
Amber 
1 Green 
2 Red 
3 Off 
GDA 
This command allows you to show all of the DACs (Digital to Analog Converter).  When 
selecting the option you need, enter the appropriate single digit number and hit enter. 
The camera returns… 
3:Gain F_odd = 0.490V 
 
8:GainF_even = 0.490V 
2:GainC_odd = 0.235V 
 
6:GainC_even = 0.235V 
4:Offset_odd = 1.199V 
 
7:Offset_even = 1.199 
1:CML_odd = 1.425V  
 
5:CML_even = 1.425 
SDN 
This command allows you to select one of the above DAC numbers, and change its value. 
Example:  SDN + enter + 486 + enter                 enter value between 0 - 1023 
GDN 
This command allows you to verify what you just did under the SDN command. 
Example:  you would input the following  GDN + enter + 1 
The camera returns a value between    0 - 1023 
SAP 
Store in Flash both correction memories, all registers and DAC values. 
 
 
                  Value      Function 
      Store all parameters   
0           Default factory calibrate 
 
 
 
1           User 
 
 
 
2           User 
RAP 
Load from flash to camera.  Recall all parameters. 
 
 
                Value      Function 
 
 
 
0         Default factory calibration 
 
 
 
1         User 
 
 
 
2         User 
Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 17 of 42