ALTINEX AP445-401 Benutzerhandbuch
SPECIAL APPLICATION
400-0422-001
15
7.5 SUMMARY OF COMMANDS
1)
[SIDn]
Set ID number of the unit.
2)
[RSI]
Reset ID of the unit to 0.
3)
[RSN]
Return unit ID number.
4)
[VER]
Display firmware version.
5)
[C]
Display current status.
6)
[CnS]
Display/save current status.
7)
[STAT]
Display current status.
8)
[STATS]
Display/save current status.
9)
[CLR]
Retrieve default settings.
10) [IN]
Select input.
11) [INR]
Select input/recall settings.
12) [MODER]
Select output resolution.
13) [MUTE]
On-screen display ON/OFF.
14) [VCR]
Toggle VCR/Standard mode.
15) [BRIGHTn]
Set Brightness level.
16) [BRIGHT]
Display/select Brightness.
17) [CONTRn]
Set Contrast level.
18) [CONTR]
Display/select Contrast.
19) [COLORn]
Set Color level.
20) [COLOR]
Display/select Color.
21) [SHARPn]
Set Sharpness level.
22) [SHARP]
Display/select Sharpness.
23) [HUEn]
Set Hue level.
24) [HUE]
Display/select Hue.
25) [VLOA]
Set audio level.
26) [SEL]
Adjust audio level.
27) [MODEN]
Noise Reduction ON/OFF.
28) [MODEA]
Aspect Ratio Wide/Standard.
29) [FREEZ]
Freeze the displayed image
30) [LOCKFP]
Lock front panel buttons.
31) [ + ]
Increment by one.
32) [ - ]
Decrement by one.
33) […S]
Save one parameter.
34) [HELP]
Display RS-232 commands.
TROUBLESHOOTING GUIDE
8
We have carefully tested and have found no
problems in the supplied AP445-401. However, we
would like to offer suggestions for the following:
problems in the supplied AP445-401. However, we
would like to offer suggestions for the following:
8.1 NO RESPONSE FROM PANEL
Cause 1:
The front panel is locked.
Solution:
Connect to the AP445-401 using
standard RS-232 communication.
Check the status [STAT] and verify
the front panel is “Unlocked”. If there
is still no response, please call
Altinex at (714)-990-2300.
standard RS-232 communication.
Check the status [STAT] and verify
the front panel is “Unlocked”. If there
is still no response, please call
Altinex at (714)-990-2300.
8.2 NO DISPLAY
Cause 1:
The source has a problem.
Solution:
Check the source and make sure
that there is a signal present and all
source connections are correct. If
the source is working and there is
still no display, see Cause 2.
that there is a signal present and all
source connections are correct. If
the source is working and there is
still no display, see Cause 2.
Cause 2:
The correct input is not selected.
Solution:
Select the input type from the front
panel or RS-232 bus. (See RS-232
accessible commands in Section 7).
If no display is present, see
Cause 3.
panel or RS-232 bus. (See RS-232
accessible commands in Section 7).
If no display is present, see
Cause 3.
Cause 3:
Cable connections are incorrect.
Solution:
Make sure that cables are properly
connected. Also, make sure that the
continuity and wiring are good. If
there is still no display present, see
Cause 4.
connected. Also, make sure that the
continuity and wiring are good. If
there is still no display present, see
Cause 4.