ALTINEX AP445-401 Manuel D’Utilisation

Page de 17
SPECIAL APPLICATION
400-0422-001
15
7.5 SUMMARY OF COMMANDS
1)
[SIDn]
Set ID number of the unit.
2)
[RSI]
Reset ID of the unit to 0.
3)
[RSN]
Return unit ID number.
4)
[VER]
Display firmware version.
5)
[C]
Display current status.
6)
[CnS]
Display/save current status.
7)
[STAT]
Display current status.
8)
[STATS]
Display/save current status.
9)
[CLR]
Retrieve default settings.
10) [IN]
Select input.
11) [INR]
Select input/recall settings.
12) [MODER]
Select output resolution.
13) [MUTE]
On-screen display ON/OFF.
14) [VCR]
Toggle VCR/Standard mode.
15) [BRIGHTn]
Set Brightness level.
16) [BRIGHT]
Display/select Brightness.
17) [CONTRn]
Set Contrast level.
18) [CONTR]
Display/select Contrast.
19) [COLORn]
Set Color level.
20) [COLOR]
Display/select Color.
21) [SHARPn]
Set Sharpness level.
22) [SHARP]
Display/select Sharpness.
23) [HUEn]
Set Hue level.
24) [HUE]
Display/select Hue.
25) [VLOA]
Set audio level.
26) [SEL]
Adjust audio level.
27) [MODEN]
Noise Reduction ON/OFF.
28) [MODEA]
Aspect Ratio Wide/Standard.
29) [FREEZ]
Freeze the displayed image
30) [LOCKFP]
Lock front panel buttons.
31) [ + ]
Increment by one.
32) [ - ]
Decrement by one.
33) […S]
Save one parameter.
34) [HELP]
Display RS-232 commands.
TROUBLESHOOTING GUIDE
8
We have carefully tested and have found no 
problems in the supplied AP445-401.  However, we 
would like to offer suggestions for the following:
8.1  NO RESPONSE FROM PANEL
Cause 1:
The front panel is locked.
Solution:
Connect to the AP445-401 using 
standard RS-232 communication. 
Check the status [STAT] and verify 
the front panel is “Unlocked”. If there 
is still no response, please call 
Altinex at (714)-990-2300.
8.2  NO DISPLAY
Cause 1:
The source has a problem.
Solution:
Check the source and make sure 
that there is a signal present and all 
source connections are correct. If 
the source is working and there is 
still no display, see Cause 2.
Cause 2:
The correct input is not selected.
Solution:
Select the input type from the front 
panel or RS-232 bus. (See RS-232 
accessible commands in Section 7). 
If no display is present, see 
Cause 3. 
Cause 3:
Cable connections are incorrect.
Solution:
Make sure that cables are properly 
connected. Also, make sure that the 
continuity and wiring are good. If 
there is still no display present, see 
Cause 4.