locatInG the new water heater
approVals
Model and ratInG
facts to consIder aBout the locatIon
Installation  of  the  water  heater  must  be  accomplished  in  such  a 
manner that if the tank or any connections should leak, the flow will 
not cause damage to the structure. For this reason, it is not advisable 
to install the water heater in an attic or upper floor.
Water heater life depends upon water quality, water pressure and 
the environment in which the water heater is installed. Water heaters 
are  sometimes  installed  in  locations  where  leakage  may  result  in 
property damage. However, unanticipated damage can be reduced 
or  prevented  by  a  leak  detector  or  water  shut-off  device.  These 
devices are available from some plumbing supply wholesalers and 
retailers:
Carefully choose a location for the new water heater. The placement 
is a very important consideration for the safety of the occupants in 
the building and for the most economical use of the equipment. 
The water heater should be located in an area where the general 
public does not have access. If a suitable area is not available, a 
cover should be installed over the thermostat to prevent tampering.
Whether replacing an old water heater or putting the water heater in 
a new location, the following critical points should be observed. The 
water heater should be located:
1.   On  a  level  surface.  Shim  the  channel  type  skid  base  as 
necessary if levelling is required.
2.   Near a floor drain. The heater should be located in an area where 
leakage of the tank or connections will not result in damage to the 
area adjacent to the heater or to lower floors of the structure.
3.  The discharge opening of the temperature and pressure relief 
valve should always be piped to an open drain.
4.  Close  to  the  point  of  major  hot  water  usage  and  the  power 
supply.
Hot water piping and branch circuit wiring should be as short as possible.
Insulate hot and cold water piping where heat loss and condensation 
may be a problem.
Heater  construction  permits  installation,  maintenance,  and  service 
work to be performed from the front of the unit. Ensure enough frontal 
clearance so that the piping and coil may be removed from the tank.
Suggested clearances from adjacent surfaces are 12 inches on top, 
for access to the unit.
The heater may be installed on or against combustible surfaces. The 
left side and back may be placed flush against adjacent surfaces.
The temperature of the space in which the water heater is installed 
must not go below 32°F or above 122°F.
asMe