7.2 Programming Worksheets
Keypad and Function Key Programming
[000] Function 
Key 
Programming 
[1] Function Key 1 Assignment
[2] Function Key 2 Assignment
[3] Function Key 3 Assignment
[4] Function Key 4 Assignment
[5] Function Key 5 Assignment
Function Key Options:
[001]-[002] Zone Definitions
Unless indicated otherwise, default values apply to NA, EU and CP-01 
SIA FAR CP-01 defaults are indicated in gray text.
EU Defaults are indicated by a Superscript EU e.g., (
   EU
)
 
or  (
 EU
005
)
NA Defaults are indicated by a Superscript NA e.g., ( 
 NA
)
 
or (
(NA
005
)
 See “Local Keypad Programming” on page 30. for additional options.
  
00
  Null Key
  09  Future Use
 *27 Disarm
  01
  Future Use
  10  Future use
 *29 [A]uxilliary Alarm
  02
  Future Use
  11  Future use
 *30 [P]anic
  03
  Stay Arm 
  12  Future Use
  04
  Away Arm
  13  [ ][7][1] Command Output #1
 * Applies to Key Fobs only
  05
  [ ][9] No Entry Arm
  14  [ ][7][2] Command Output #2
See Section [804] Subsection [61]-[76]
  
06
  [ ][4] Chime On / Off
  15  For Future Use
  07
  Future Use
  16  [ ][0] Quick Exit
  08
  [ ][1] Bypass Mode
  17  [ ][1] Reactivate Stay/Away Zones
Key 1
Key 2
Key 3
Key 4
Key 5
Keypad Defaults
03  ___
04  ___
06  ___
08  ___
16  ___
00  Null Zone (Not Used)
13  24 Hour Gas*
25  Interior Delay*
01  Delay 1*
14  24 Hour Heat*
26  24 Hour Non-alarm*
02  Delay 2*
15  24 Hour Medical*
27-31  Future Use
03  Instant*
16  24 Hour Panic*
32  Instant Stay/Away*
04  Interior*
17  24 Hour Emergency*
33-35  Future Use
05  Interior, Stay/Away*
18  Future Use
36  24 Hr. Non-latching Tamper
06  Delay, Stay/Away*
19  24 Hour Water*
37  Night Zone
07-08  Future Use
20  24 Hour Freeze*
87  Delayed 24 Hr. Fire (Wireless)**
09  24 Hour Supervisory (Hardwired)
21  Future Use
88  Standard 24 Hr. Fire (Wireless)**
10  24 Hour Supervisory Buzzer*
22  Momentary Keyswitch Arm*
89  Auto-verified 24 Hr. Fire (Wireless)**
11  24 Hour Burglary*
23  Maintained Keyswitch Arm (Hardwired)* 
12  Future Use
24  Future Use
*For burglary applications only
** For residential fire applications only
Section
Zone
Default
Section
Zone
Default
Section
Zone
Default
Section
Zone
Default
[001]
01
01
 I_____I_____I
[001]
09
00
 I_____I_____I
[002]
17
00
 I_____I_____I
[002]
25
00
 I_____I_____I
02
03
 I_____I_____I
10
00
 I_____I_____I
18
00
 I_____I_____I
26
00
 I_____I_____I
03
03
 I_____I_____I
11
00
 I_____I_____I
19
00
 I_____I_____I
27
00
 I_____I_____I
04
03
 I_____I_____I
12
00
 I_____I_____I
20
00
 I_____I_____I
28
00
 I_____I_____I
05
04
 I_____I_____I
13
00
 I_____I_____I
21
00
 I_____I_____I
29
00
 I_____I_____I
06
04
 I_____I_____I
14
00
 I_____I_____I
22
00
 I_____I_____I
30
00
 I_____I_____I
07
04
 I_____I_____I
15
00
 I_____I_____I
23
00
 I_____I_____I
31
00
 I_____I_____I
08
04
 I_____I_____I
16
00
 I_____I_____I
24
00
 I_____I_____I
32
00
 I_____I_____I
WWW.DIYALARMFORUM.COM