Self Contained Wireless Alarm System v1.0
48
Section 9: Testing & Troubleshooting
Testing:
Power up system
Program options as required (See Programming Section)
Violate, then restore zones
Verify correct Reporting Codes are sent to the Central Station
Troubleshooting:
Power up system
Enter 
✱[2] to view Troubles
Perform actions indicated in the tables below.
Trouble Summary:
Trouble [1]
✱ Service Required - Press [1] for more information
    Low Battery
    General System Trouble
    General System Tamper
Trouble [2]    AC Trouble
Trouble [3]    Telephone Line Trouble
Trouble [4]    Failure to Communicate
Trouble [5]
✱ Zone Fault -Press [5] for more information 
Trouble [6]
✱ Zone Tamper - Press [6] for more information
Trouble [7]
✱ Wireless Device Low Battery - Press [7] for more information
Trouble [8]    Loss of Time or Date
Trouble
Cause
Troubleshooting
Trouble [1] Service Required                        Press [1] to determine specific trouble
Low Battery
Main panel battery less than 7.2V
DC
NOTE: This trouble condition will not 
clear until the battery voltage is 7.6V
DC
 
min., under load.
NOTE: If battery is new allow 24 Hrs. for battery to charge.
Verify voltage measured across AC terminals is 16-18 VAC. 
Replace transformer if required.
Disconnect then reconnect battery leads.
General System Trouble
The system has detected the presence 
of a RF Jam for 20s or communications 
with the wireless receiver have failed 
causing a Hardware Fault.
Check Event buffer to determine specific trouble.
If Buffer logs RF Jam trouble:
Check for external 433MHZ signal sources
To disable RF Jam: enable Option [7] in program section [804]
subsection [90].
If Buffer logs Hardware fault - Replace Panel
General System Tamper
Cover tamper tripped
Verify that tamper button is installed into back plate
Verify that keypad (cover) is secured to backplate.
Trouble [2] AC Failure
No AC at panel AC input terminals
Verify voltage measured across AC terminals is 16-18VAC. 
Replace transformer if required.
Trouble [3] Telephone Line Trouble
Phone Line Voltage at TIP, RING on 
main panel less than 3V
DC
Measure the voltage across TIP and RING on the panel:
• No phone off-hook – 50VDC (approx.)
• Any phone off-hook – 5VDC (approx.)
Wire incoming line directly to TIP and RING. 
• If trouble clears, check wiring or the RJ-31x phone jack.