DSCover Satellite Products Home Security System SCW904x Benutzerhandbuch

Seite von 64
Appendix E: 2-Way Audio Verification (SCW9047 only)
57
Appendix E: 2-Way Audio Verification (SCW9047 only)
The following information is intended for use by the Central Station Operator.
The SCW9047 Audio Verification provides Talk and Listen-in capability for audio verification of alarms.  This allows the central station to 
communicate with the occupants through the microphone and speaker of the alarm system. The commands indicated below are a subset of the 
SIA Audio Verification Standard (November 11, 1997)
The 2-way Audio Session
1.
Zone Violation: A 2-way audio session begins with the violation of a zone that has zone attribute 9 enabled.
By default the following do NOT initiate a 2-way session:
Fire Zones, zone 87, 88, 89 and the Fire Key
Supervisory zones, zones 9 and 10
24 Hr Freeze zone, zone 20
By default 1-way audio (Listen-in only) is initiated by the following:
Silent Panic events (Silent [P], Silent Panic zone)
Duress alarm
Silent zone alarm (Zone attribute 1 OFF)
NOTE: The Operator can NOT switch to Talk mode (Speaker is always OFF
2.
Communication to the Monitoring Station: When the appropriate Alarm is triggered one of the following reporting codes/actions is sent to 
the monitoring station.
3.
Alerting the Operator: When the reporting code is received by the monitoring station or a 2-way session is automatically initiated, a 2-way 
Initiation (Start) tone will be sounded to alert the operator. A high (1800 Hz) tone and a low (900 Hz) tone are used to generate the following 
Session Tones. Short tone duration is 100ms. Long tone duration is 1 second.:
Format
Reporting Code/Event
SIA
L90
Contact ID
606
BPS
Communicates the Event, then automatically enters into 2-way Audio mode
2-way Initiation (Start) Tone: 
3 Hi Tones (Short)
After the third short Hi tone has sounded, the system switches directly into Listen-in mode without 
a keypress from the monitoring station.
Reminder Tones:
1 Hi Tone (Short)
1 Short Hi Tone indicates 20 seconds are left in the audio session
1 low Tone
1 Short Low Tone indicates 10 seconds are left in the audio session
Subsequent Alarm:
1 Hi Tone Long
1 long Hi Tone indicates a new alarm event if Section [023] Option 6 (
New Alarms will not discon-
nect 2-way Audio
) is enabled, alarms will be delayed. If disabled the audio session will terminate. 
NOTE: Receiving a subsequent alarm event tone will not restart the 90 second session timer.
Subsequent Fire Event:
Hi, Low, Hi 
(Short)
3 short (100ms) tones Hi, Low, Hi indicates a new Fire alarm if Section [023] Option 6 (
New Alarms 
will not disconnect 2-way Audio
) is enabled. If disabled the audio session will terminate.
NOTE: Receiving a subsequent Fire alarm event tone will not restart the 90 second session timer.