DCS Computer Hardware dCS 974 Benutzerhandbuch

Seite von 131
dCS 974 User Manual
 Manual for Software Version 1.0x
dCS Ltd 
May 2001
Manual part no: DOC1241121A1
Page 14
Document No: OS-MA-A0124-112.1A1
Contact 
dCS
 on + 44 1799 531 999 
email to: more@dcsltd.co.uk
(inside the UK replace + 44 with 0)
web site: www.dcsltd.co.uk
Syncing to an AES/EBU Reference
If you want to synchronise your system to an AES/EBU Reference from a
Master Clock (such as the dCS 992) or other stable source, do the following:
do this: 
Set the Master Clock sample rate to match the source (probably 44.1 or
48kS/s).
do this: 
Connect either an AES/EBU or Wordclock output from the Master Clock to the
clock input on the source equipment and ensure it is locked.
do this: 
Connect another AES/EBU output from the Master Clock to the 
AES Ref Loop
IN
 connector on the dCS 974 rear panel.
do this: 
Scroll down the 
Sample Rate Conversion
 menu to 
Sync Source
 and press
the 
 button. Scroll down the list to 
AES Loop Terminated
 and press 
Set
.
The 
Unlocked
 indicator will light for a few seconds, then turn off as the unit
re-locks.
do this: 
Proceed to Step 3.