12.  To change the parameter, type in a new value, then press Enter. If 
you wish to leave the parameter as it was, simply press Enter. A 
prompt for the next parameter will appear.  
13.  When all parameters in the currently selected section are complete 
you will again be prompted to select a menu item. Select another 
section and continue the configuration process. 
Saving Configuration Settings 
When all categories have been configured you must save your configuration 
to the MES1A/B.  
To  Save the configuration settings to the MES1A/B, at the 
Select 
Command or parameter set (1..4) to change: 
prompt type S.  
Quitting Without Saving 
To  Quit the configuration session without saving, type Q. The background 
color will change to gray and the MES1A/B will re-start without updating the 
configuration settings. 
Reconfiguring to Factory Settings 
The MES1A and MES1B come from the factory preconfigured for correct 
operation with their respective interfaces. The following procedure describes 
how you can return the MES1A and MES1B to their original factory settings. 
To Reconfigure the MES1A to Factory Settings: 
Type  D at the 
Select Command or parameter set (1..4) to 
change: 
prompt. The Configuration Menu is updated with the new settings 
displayed. 
To Reconfigure the MES1B, to Factory Settings: 
14.  Type  D at the 
Select Command or parameter set (1..4) 
to change: 
prompt.  
15.  Type  2  to enter the Serial & Mode Settings section and set the 
Serial Mode for RS-485 Two-Wire (see the next section for 
details).