23
 
Auto-IP 
If a DHCP server is NOT available on the network, the MES1A/B will revert 
to Auto-IP and generate its own IP address in the 169.254.xxx.xxx range. 
Static IP Address 
The IP address of the MES1A/B can be changed via the Telnet Configuration 
Menu interface.  
To determine an appropriate static IP address, consult your network 
administrator. The Device Installer Help feature also provides some useful 
information related to IP addressing. 
17.
 
At the 
Select Command or parameter set (1..4) to 
change: 
prompt, type 1. 
 
18.
 
At the 
IP Address (000)
prompt
 
o
  To keep the current setting, press Enter  
o
  To change the IP address, type the first octet 
ƒ  Press Enter to accept the change 
ƒ  Repeat for all octets 
19.  Press Enter to accept the new IP address 
After the new settings have been accepted they will appear in the 
Configuration Menu. After the Configuration has been saved to the 
MES1A/B, the new settings will appear in the Device Details tab. 
The IP Address can also be changed from the Device Installer menu. See 
Chapter 5 for details. 
Default Gateway 
A  Default Gateway address is only required if your MES1A/B must 
communicate with devices on remote TCP/IP networks through a router or 
gateway. The default value for this parameter is 
---not set---.
 
•  If you DO NOT require remote communication, type N  or just press 
Enter at the 
Set Gateway IP Address (N)
 prompt. 
•  If you DO require remote communication through a router or gateway, 
type Y. The 
Gateway IP Address: (000)
 prompt appears. Enter the 
IP address of the default gateway within your local network by typing 
each address octet followed by pressing Enter.