Set Power-up States Command 
 
The Set Power-up States command is used to set the states of 
output lines when the module's power is recycled.  This command 
requires two data bytes.  These data bytes specify the output state 
of each output line.  The first data byte represents the eight most 
significant I/O lines (15 - 8).  The second data byte represents the 
eight least significant I/O lines (7 - 0).  If a bit position is set to a "0" 
then the state of that output line will be set LOW.  If a bit position is 
set to a "1" then the state of that output line will be set HIGH. 
 
Command: !{addr}SS 
Argument: {I/O 
msb}{I/O 
lsb} 
Response: none 
ASCII Example: !0SSÛ@ 
Dec. Example:  !0SS<219><64> 
Hex. Example:  !0SS<DB><40> 
Bin. Example:  !0SS<11011011><01000000> 
Description:  Set module 0's (decimal 48) power-up states. The first 
byte sets output lines #15, 14, 12, 11, 9, & 8  HIGH and output lines 
#13, & 10 LOW at power-up; the second byte sets output line #6 
HIGH and output lines #7, 5, 4, 3, 2, 1, & 0 LOW at power-up.  
NOTE: If any of these lines are defined as inputs the bit settings are 
ignored. 
 
Read Configuration Command 
 
The Read Configuration command returns the module's I/O 
definitions, the outputs power-up state, the module's address, and 
the turn-around delay.  Six data bytes are returned.  The first two 
data bytes contain the definition of the eight most significant I/O lines 
(15 - 8) and the eight least significant I/O lines (7 - 0) respectively.  If 
a bit position is set to a "0" the I/O line is defined as an input, if set to 
a "1" the I/O line is defined as an output.  The second two data bytes 
contain the power-up states of the most significant output lines (15 - 
8) and the least significant output lines (7 - 0) respectively.  If a bit 
position is set to a "0" the power-up state of the output will be LOW, 
if set to a "1" the output will be HIGH.  The fifth data byte is the 
module's address.  The sixth data byte is the turn-around delay. 
 
Command: !{addr}RC 
Argument: none 
Response:  definition of the sixteen I/O lines in two 8 bit bytes, and 
the power-up states in two 8 bit bytes. (shown in bold face) 
16 485SDD16-1005 
Manual 
B&B Electronics  --  707 Dayton Road  --  Ottawa, IL  61350 
PH (815) 433-5100  --  FAX (815) 433-5104
 
ASCII Example: !9RCUAP@9
♦ 
Dec. Example:  !9RC<85><65><80><64><57><04
Hex. Example:  !9RC<55><41><50><40><39><04
Bin. Example: !0RC<01010101><01000001><01010000><01000000
<00111001><00000100
Description:  Read module 9's (decimal 57) configuration. The first 
byte (MSB of I/O definitions) - I/O lines #14, 12, 10, & 8  are outputs 
and I/O lines #15, 13, 11, & 9 are inputs; the second byte (LSB of 
I/O definitions) - I/O lines #6, & 0 are outputs and I/O lines #7, 5, 4, 
3, 2, & 1 are inputs; the third byte (MSB of output power-up states) - 
output lines #14, & 12 HIGH  and output lines #10, & 8 LOW at 
power-up; the fourth byte (LSB of output power-up states) - output 
line #6 HIGH and output line #0 LOW at power-up; the fifth byte 
(module address) is set ASCII "9" (decimal 57); the sixth byte (turn-
around delay) is a decimal 4.