Baumatic BCG520BL Benutzerhandbuch
Gas adjustment (Conversion to LPG for the hob top)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o
Remove the pan supports, burner cap and burner rings.
o
Unscrew the injector and replace it with the required injector for
the new gas supply according to the table below.
the new gas supply according to the table below.
Burner Type
Gas Type Pressure
Mbar
Injector
Marking
Marking
(1/100mm)
Power
(Kw)
Max Min
Natural
Gas
20 72
Auxiliary (Small)
Liquid Gas 28..30/37
50
1 0.3
Natural
Gas
20 97
Semi Rapid
(Medium)
Liquid Gas 28..30/37
65
1.75 0.6
Natural
Gas
20 115
Rapid (Large)
Liquid Gas 28..30/37
85
3 1
o
When all four jets have been replaced, reassemble all the
burners carefully, taking particular care to make sure that the
burners and burner caps are aligned properly.
burners carefully, taking particular care to make sure that the
burners and burner caps are aligned properly.
o
After changing the injectors YOU MUST change the minimum
flow rate.
flow rate.
32