Baumatic BCG520BL Benutzerhandbuch

Seite von 44
Gas adjustment (Conversion to LPG for the hob top) 
 
All work must be carried out by a GASSAFE 
registered engineer. 
 
 
IMPORTANT: Always isolate the cooker from the electricity 
supply before changing the injectors and/or adjusting the 
minimum flow of the burners. 
 
o
 
Remove the pan supports, burner cap and burner rings.  
 
o
 
Unscrew the injector and replace it with the required injector for 
the new gas supply according to the table below.  
 
Burner Type 
Gas Type  Pressure 
Mbar 
Injector 
Marking 
(1/100mm) 
Power 
(Kw) 
Max Min 
Natural 
Gas 
20 72 
Auxiliary (Small) 
Liquid Gas  28..30/37 
50 
1 0.3 
 
Natural 
Gas 
20 97 
Semi Rapid 
(Medium) 
Liquid Gas  28..30/37 
65 
1.75 0.6 
Natural 
Gas 
20 115 
Rapid (Large) 
Liquid Gas  28..30/37 
85 
3 1 
 
 
o
 
When all four jets have been replaced, reassemble all the 
burners carefully, taking particular care to make sure that the 
burners and burner caps are aligned properly. 
 
o
 
After changing the injectors YOU MUST change the minimum 
flow rate.  
 
 
 
 
 
 
32