Whirlpool WGG755S0BH Anleitung Für Quick Setup

Seite von 40
9
3. Use a 
¹⁵⁄₁₆" combination wrench and an adjustable wrench to 
attach the flexible connector to the adapters. Check that 
connector is not kinked.
IMPORTANT: All connections must be wrench-tightened. Do 
not make connections to the gas pressure regulator too tight. 
Making the connections too tight may crack the regulator and 
cause a gas leak. Do not allow the regulator to turn when 
tightening the fittings. 
4. Gas supply pipe must be located within the shaded area as 
shown in the “Cabinet Dimensions” illustration in “Location 
Requirements” section.
Complete connection
1. Open the manual shutoff valve in the gas supply line. The 
valve is open when the handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. If bubbles appear, a 
leak is indicated. Correct any leak found.
3. Remove cooktop burner caps and grates from parts 
package. Align recess in burner caps with pins in burner 
base. Burner caps should be level when properly positioned. 
If burner caps are not properly positioned, surface burners 
will not light. Place burner grates over burners and caps.
4. Plug into a grounded 3 prong outlet.
Verify Anti-Tip Bracket Is Installed and 
Engaged
1. Place the outside of your foot against the bottom front of the 
oven door to keep the unit from moving, and grasp the lower 
right or left side of the control panel as shown.
NOTE: If your countertop is mounted with a backsplash, it 
may be necessary to grasp the range higher than is shown in 
the illustration.
2. Slowly attempt to tilt the range forward. 
If you encounter immediate resistance, the range foot is 
engaged in the anti-tip bracket.
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½" male 
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound.
H. Adapter
A. Gas pressure regulator
B. Adapter
C. Flexible connector
D. Manual shutoff valve
A. Closed valve
B. Open valve
A
B
C
D
E
F
G
H
Adaptor
A
B
C
D
A
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING