Electrical Requirements
Before you move your ice maker into its final location, it is 
important to make sure you have the proper electrical 
connection:
A 115 Volt, 60 Hz., AC only 15-amp electrical supply, properly 
grounded in accordance with the National Electrical Code and 
local codes and ordinances, is required. 
It is recommended that a separate circuit, serving only your ice 
maker, be provided. Use a receptacle which cannot be turned off 
by a switch or pull chain. 
Recommended grounding method
For your personal safety, this appliance must be grounded. This 
appliance is equipped with a power supply cord having a 3 prong 
grounding plug. To minimize possible shock hazard, the cord 
must be plugged into a mating, 3 prong, grounding-type wall 
receptacle, grounded in accordance with the National Electrical 
Code and local codes and ordinances. If a mating wall receptacle 
is not available, it is the personal responsibility of the customer to 
have a properly grounded, 3 prong wall receptacle installed by a 
qualified electrician.
Water Supply Requirements
A cold water supply with water pressure of between 30 and 
120 psi (207 - 827 kPa) is required to operate the ice maker. If 
you have questions about your water pressure, call a licensed, 
qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a 
reverse osmosis system going to the water inlet valve of the ice 
maker needs to be between 30 and 120 psi (207 - 827 kPa).
If a reverse osmosis water filtration system is connected to your 
cold water supply, the water pressure to the reverse osmosis 
system needs to be a minimum of 40 to 60 psi (276 - 414 kPa). 
The reverse osmosis system must provide 1 gal (3.79L) of water 
per hour to the ice maker for proper ice maker operation.  
If the water pressure to the reverse osmosis system is less than 
40 to 60 psi (276 - 414 kPa):
Check to see whether the sediment filter in the reverse 
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill 
after heavy usage.
If you have questions about your water pressure, call a licensed, 
qualified plumber.
Leveling
It is important for the ice maker to be level in order to work 
properly. Depending upon where you install the ice maker, you 
may need to make several adjustments to level it. You may also 
use the leveling legs to lower the height of the ice maker for 
undercounter installations. 
Tools needed:
Gather the required tools and parts before starting installation.
Carpenter’s level
Adjustable wrench
NOTE: It is easier to adjust the leveling legs if you have another 
person to assist you.
1. Move the ice maker to its final location. 
NOTE: If this is a built-in installation, move the ice maker as 
close as possible to the final location.
2. Place a carpenter’s level on top of the product to see if the ice 
maker is level from front to back and side to side.
3. Push up on the top front of the ice maker, and then locate the 
leveling screws that are on the bottom front of the ice maker. 
4. Using an adjustable wrench, change the height of the legs as 
follows:
Turn the leveling leg to the right to lower that side of the 
ice maker.
Turn the leveling leg to the left to raise that side of the ice 
maker.
NOTE: The ice maker should not wobble. Use shims to add 
stability when needed. 
5. Push up on the top rear of the ice maker and locate the 
leveling legs that are on the bottom rear of the ice maker. 
6. Follow the instructions in Step 4 to change the height of the 
legs.
7. Use a carpenter’s level to recheck the ice maker to see that it 
is even from front to back and side to side. If the ice maker is 
not level, repeat steps 3 to 6. If the ice maker is level, go to 
the “Connect Water Supply” section.
Connect Water Supply
Read all directions thoroughly before you begin.
IMPORTANT:
Plumbing shall be installed in accordance with the 
International Plumbing Code and any local codes and 
ordinances.
Use copper tubing and check for leaks.
Install copper tubing only in areas where temperatures will 
remain above freezing.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING