C O M M A N D   L I N E   I N T E R F A C E
Command Summary
350-8697
DGy Model 201 User Guide
109
. . . . .
PREVMARK 
(none)
The 
PREVMARK
 command sends the recorder to 
the previous event mark from the current position, 
and cues there. To play from that spot you must 
issue a 
PLAY
 or Pause command.
PREVMARK
 will only seek within the current clip, 
and will not wrap.
SeekToMARK
<mark number | 
description>
The 
STMARK
 command sends the recorder to the 
specified event mark, and cues there. To play from 
that spot you must issue a 
PLAY
 or Pause 
command.
STMARK
 will only seek within the current clip.
TimeCodeQuery
[H | F]
Returns the timecode at the current disk position. 
Only valid in PLAY or PAUSE modes.
When used without an argument, the 
TimeCodeQuery command returns the time in the 
format yyyymmddhhmmss. 
When used with the optional H argument, the 
TimeCodeQuery returns the replay timecode with 
resolution in milliseconds with the format 
yyyymmddhhmmssxxx where the final three digits 
(xxx) represent the fractional time in milliseconds.
When used with the optional F argument, the 
TimeCodeQuery command returns the replay 
timecode using the frame number. The first frame in 
a file is identified as frame 0. Note that a clip may 
consist of multiple files and that the maximum file 
size is approximately 1.8 GB. This command option 
is typically used for debug only.
Table 6-10.  
DGy 201 Play and Record Commands (Continued)
Command
Arguments
Description