Toshiba TOSVERT VF-S11 Gebrauchsanleitung

Seite von 68
E6581222
62
■  Monitor parameters    * These parameters are read-only (monitor-only) parameters.
Communi-
cation No.
Title
Function
Unit
Remarks
FC00
-
Monitor of key data (Effective data)
-
See 8.4.
FC01
-
Monitor of inverter keypad data
-
See 8.4.
FC90
-
Trip code
-
See 8.2.
FC91
-
Alarm code
-
See 8.2.
FD00
-
Operation frequency (current frequency)
0.01Hz
FD01
-
Inverter status (current status)
-
See 8.2.
FD06
-
Input terminal information (current information)
-
See 8.3.
FD07
-
Output terminal information (current information)
-
See 8.3.
FD42
-
Inverter status2 (current status)
-
See 8.2.
FD49
-
Inverter status3 (current status)
-
See 8.2.
FE00
-
Operation frequency 
*5
0.01Hz
FE01
-
Inverter status 
*5
-
See 8.2.
FE02
-
Operation frequency command (actual instruction) 
*5
0.01Hz
FE03
-
Load current
0.01%
FE04
-
Input Voltage
0.01%
FE05
-
Output voltage 
*5
0.01%
FE06
-
Input terminal information 
*5
-
See 8.3.
FE07
-
Output terminal information 
*5
-
See 8.3.
FE08
-
CPU1 version
-
FE09
-
EEPROM version
-
FE10
-
Past trip 1
-
See 8.2.
FE11
-
Past trip 2
-
See 8.2.
FE12
-
Past trip 3
-
See 8.2.
FE13
-
Past trip 4
-
See 8.2.
FE14
-
Cumulative operation time
1H
FE15
-
Primary frequency (compensated frequency) 
*5
0.01Hz
FE16
-
Estimated motor operation frequency 
*5
0.01Hz
FE18
-
Torque
0.01%
FE20
-
Torque current 
*5
0.01%
FE21
-
Excitation current 
*5
0.01%
FE22
-
Analog (VIA) input frequency 
*5
0.01Hz
FE26
-
Motor (Electronic-thermal) load factor 
*5
1%
FE27
-
Inverter load factor 
*5
1%
FE29
Input power
0.01KW
FE30
-
Output power 
*5
0.01KW
FE35
-
Analog input value VIA
10-bit resolution (data range: 0 to 1023)
-
See 8.3.
FE36
-
Analog input value VIB
10-bit resolution (data range: 0 to 1023)
-
See 8.3.
FE42
-
Inverter status2
-
See 8.2.
FE45
-
Command mode(CMOD) status
-
See 8.2.
FE46
-
Frequency mode(FMOD) status
-
See 8.2.
FE49
-
Inverter status3
-
See 8.2.
FE70
-
Rated current
0.1A
FE71
-
Rated voltage
0.1V
FE73
-
CPU2 version
-
FE75
-
monitor of inverter number Hard SW
-
FE76
-
Integral Input power
0.01kWh
FE77
-
Integral Output power
0.01kWh
FE79
-
Life alarm information
-
See 8.2.
FE80
-
Cumulative power-on time
1H
*5: If a trip occurs, data immediately before its occurrence is displayed.