Appendix 2 Response time
The communication response time can be calculated from data communication time and inverter
processing time.
   
When wishing to know the communication response time, calculate using the fol-
lowing as a reference
■  Data transmission time
   
bits
 
of
 
number
d
transmitte
 
bytes
 
of
 
number
rate
 
baud
1
 
time
 
on
transmissi
 
Data
×
×
=
* Number of bits = start bit + data frame length + parity bit + stop bit
* Minimum number of bits = 1 + 8 + 0 + 1 = 10 bits
* Maximum number of bits = 1 + 8 + 1 + 2 = 12 bits
<An example of the calculation of the transmission time: 19200 bps, 8 bytes, 11 bits>
4.6ms
11
8
19200
1
 
time
 
on
transmissi
 
Data
=
×
×
=
■  Data processing time of inverter
Data processing time: maximum 20ms
Inverter 
→ PC
Data transmission time
Response time
PC 
→ Inverter
Data transmission time