15 Analog RGB Input
DOS/V Personal 
computer
POD
COM1
COM2
MJ1
MJ2
Editor Port
Touch Switch
UG00C-T
4. Save the file, and send it to the POD.
5. Mode is changed to RUN.  In this mode, change screen over to the [RGB Input] screen.
(Windows screen is displayed.)
6. In order to execute “touch-panel emulation”,
connect between COM1 (communication port) of
the personal computer and MJ2 (touch switch)
of the POD by means of UG00C-T.
7. Insert the “Touch Panel Driver PN-WIN98/95” floppy disk supplied from GUNZE in the floppy disk drive
and, from the files stored in the floppy disk, double-click “/Serial/setup.exe”.  Then follow the directions
displayed on the screen to install the touch panel driver.
Then [Welcome!] 
 [Select destination to install] 
 [Install] 
 [Hardware setting] (See item 2 of the
notes described later.) 
 [Installation end] 
 [Install] Clicking the [OK] button here automatically
restart the personal computer.  At the same time, the POD comes in RUN mode.  Then change screen
over to the [RGB Input] screen to start Windows.
8. When Windows is started, the calibration software is automatically activated.  Set items for calibration
(see item 3 of the notes described later).
This completes the installation of the touch panel driver.
9. When it is necessary to reset the “Touch Panel Driver PN-WIN98/95”, select menus as follows:
[Start] 
 [Programs] 
 [Gunze] 
 [PN-WIN98_95 Serial] 
 [Touch panel driver].  Changes in the
setting will take effect when the personal computer is started the next time.
*
 Notes
1. It is impossible to change over to the [Main Menu] screen from the Windows screen displayed on the
POD.
2. The [Hardware setting] dialog box is prepared for installing the touch panel driver.  For [COM Port] in
this dialog box, select the COM port of the personal computer that is to be connected to the MJ port (for
touch switch) of the POD.  For [Address] and [IRQ], set the address and IRQ of the selected COM port.
When you do not know which COM port of the personal computer to connect to the MJ port (for touch
switch) of the POD, or when you do not know the address or IRQ of the COM port, refer to the
instruction manual for the personal computer.
[Baud rate: 9600], [Parity: none], [Data bits: 8] and [Stop bits: 1] are fixed.
3. With the calibration software, correct the touch position and the mouse cursor indication position.
Touch as accurately as possible the red crosses that are displayed on the screen in the order of first
point (lower left on the screen), second point (upper right on the screen), third point  (lower right on the
screen), and fourth point (upper left on the screen).  Touch operation won’t be available if the calibra-
tion setting is not correctly completed.  In such case, re-execute the setting.
4. Not that once the touch panel driver is installed, the serial port assigned for it won’t be able to be used
for other application till unless is uninstalled.
5. When your personal computer has only one COM (communication) port it is recommended to use other
personal computer for transferring POD screen.