EMERGENCIES: If a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.
Emergencies
Problem
Gas leaking from 
cracked/cut/burned 
hose.
Gas leaking from LP 
cylinder.
Gas leaking from LP 
cylinder valve.
Gas leaking between 
LP cylinder and 
regulator connection.
Fire coming through 
control panel.
Grease fire or 
continuous excessive 
flames above cooking 
surface.
Burner will not  light 
Possible Cause
Possible Cause
• Damaged hose.
• Mechanical failure due to rusting or 
mishandling.
• Failure of cylinder valve from 
mishandling or mechanical failure.
• Improper installation, connection not 
tight, failure of rubber seal.
• Fire in burner section of burner due to 
blockage.
• Too much grease buildup in burner area.
GAS ISSUES:
• Burner not engaged with control valve.
• Obstruction in burner.
• No gas flow.
• Vapor lock at coupling nut to LP cylinder.
• Coupling nut and LP cylinder valve not 
fully connected.
Prevention/Solution
Prevention/Solution
• Turn off gas at LP cylinder or at source on natural gas systems. If 
hose is cut or cracked, replace valve/hose/regulator. See LP 
Cylinder Leak Test and Connecting Regulator to the LP Cylinder.
• Replace LP cylinder.
• Turn off LP cylinder valve. Return LP cylinder to gas supplier.
• Turn off LP cylinder valve. Remove regulator from cylinder and 
visually inspect rubber seal for damage. See LP Cylinder Leak Test 
and Connecting Regulator to the LP Cylinder.
• Turn off control knob and LP cylinder valve. Allow flames to die 
down. After fire is out and appliance is cold, remove burner and 
inspect for spider nests or rust. See Natural Hazard and Cleaning 
the Burner Assembly pages.
• Turn off control knob and LP cylinder valve. Allow flames to die 
down. After cooling, clean food particles and excess grease from 
inside appliance windshield and other surfaces.
• Make sure valve is positioned inside of burner .
• Ensure burner  is not obstructed with spider webs or other matter. 
See cleaning section of Use and Care.
• Make sure LP cylinder is not empty. If LP cylinder is not empty, 
refer to “Sudden drop in gas flow.”
• Turn off knob and disconnect coupling nut from LP cylinder. 
Reconnect and retry.
• Turn the coupling nut approximately one-half to three-quarters 
additional turn until solid stop. Tighten by hand only - do not use 
tools.
Troubleshooting