LIGHTNING PROTECTION
 
For areas where a high probability of ground lightning strikes exists 
(Florida, Georgia, etc.,) additional lightning protection should be 
installed in the RS4000. Although it may not be possible to protect 
against all strikes, additional protection will substantially reduce the 
occurrence of lightning damage. Allstar’s lightning data indicates 
that the most strikes enter the RS4000 through the power lines.  
Effective protection requires that the surge current from the lightning 
strike be shunted to ground. This must be done without raising the 
potential of the circuitry in the RS4000, with respect to ground, to the 
levels that will damage the solid state circuitry. Lightning strikes 
generate enormous currents for very short periods of time. 
Unfortunately, the period of time is long enough to damage solid 
state components and many times, other components. The key to 
success is a very low resistance path from the surge protector to 
ground for these currents in addition to a surge protector that will act 
fast enough to protect the solid state circuitry. Several manufacturers 
offer suitable surge protectors.  
RIGHT HAND AND LEFT HAND INSTALLATION 
 
The RS4000 operator is wired at the factory for RIGHT HAND 
operation.  Right hand operation is described as the gate swinging in 
and to the right and where the operator is mounted to the right of the 
gate leaf - both as you look at the installation from the inside 
(secured side).  See Figure 4 for a pictorial example of a right hand 
operation.  
Left hand operation is described as the gate swinging in and to the 
left and where the operator is mounted to the left of the gate leaf - 
both as you look at the installation from the inside (secured side).  
Figure 7 diagrams depict gates and operators in a left hand set-up. 
Note the different wiring configurations for right-hand installations 
and left-hand installations (see Figure 13).  To change to a different 
handed operation the capacitor wires and limit wires must be 
changed.  For proper operation, the limits and capacitor must be 
wired as shown. 
SYNCHRONOUS OPERATION (MASTER/
SLAVE)  
Two RS4000 units in a bi-parting situation (one wired right-hand and 
one wired left hand, see above) can be configured to operate in a 
synchronous manner.  The units can be wired together to operate as 
one system, with one unit controlling the movement of both.  
Additionally, the installer can customize the installation of the 
external entrapment protection devices.  These devices can be wired 
to the primary (controlling) operator or alternately to the individual 
units as the situation dictates or the end user 
requires.    
When an external entrapment protection 
device is wired to the primary unit (such as 
would be recommended for a photoelectric 
beam across the entire opening) both units 
will  react to the detection of an obstruction, 
regardless of the location of the obstruction.  
An edge device (or similar) protecting an 
entrapment zone particular to the secondary 
unit could be wired to that unit only and 
would react individually to the detection of an 
obstruction.  Synchronous movement would 
resume once the obstruction is cleared and an 
open or close command is received by the 
primary operator. 
To obtain synchronous operation (5 Steps): 
1.  Wire the Primary Operator Terminal #14 
to Terminal #6 in the Secondary Operator. 
2.  Wire the Common Operator Terminal #0 
or #16 to the Common Operator Terminal #0 
or 16 in the Secondary Operator. 
3.  Wire the Primary Operator Terminal #15 
to Terminal #7 in the Secondary Operator. 
4.  Place the Master/Slave Jumper on the 
Primary Operator motor control board to the 
primary  (Master) position.   See Figure 19, 
Page 18. 
5.  Place the Master/Slave Jumper on the 
Secondary Operator motor control board to 
the secondary  position.   See Figure 19, Page 
18. 
 
C:
 INSTALLING THE OPERATOR 
   WARNING! 
TO REDUCE THE RISK OF DAMAGE DUE TO 
LIGHTNING, ENSURE A SOLID GROUND 
FROM THE TWIST’R GROUND WIRE IN THE 
SERVICE ENTRANCE 2 x 4 HANDY BOX TO 
THE ELECTRICAL SERVICE GROUND OR TO A 
EARTH GROUND STAKE NEAR THE TWIST’R. 
 
106515  REV  D 
Figure 13:  Left/Right Hand Installation Limit & Motor Wiring Diagram