TIMER TO CLOSE SETTING
 
The Timer to Close is controlled by the setting of the “AUTO 
CLOSE TIMER” potentiometer on the control board, see Figure 19.  
When the pot is adjusted fully counter-clockwise the Timer-To-Close 
is disabled.  Turning the pot approximately 1/4 turn clockwise will 
enable the Timer To Close function with a delay of approximately 2 
seconds between the gate reaching the full open position and 
automatically closing.  To increase the time delay continue to turn 
the pot in the clockwise direction to a maximum delay of 60 seconds 
(one minute). 
 
IT IS HIGHLY RECOMMENDED THAT AUXILIARY 
ENTRAPMENT PROTECTION DEVICES BE INSTALLED 
WHENEVER THE TIMER TO CLOSE OPTION IS 
ENABLED. 
 
APPLYING POWER TO THE OPERATOR
 
PRE-POWER CHECK LIST
 
Before applying power to the RS4000 operator for the first time, go 
through the following check list to ensure that all is in order before 
the application of power. 
1.  Check that the RS4000 power switch is off. 
2.  Check that the breaker at the power panel 
is on. 
3.  With a voltmeter on the proper scale, 
check that the line voltage at the input to 
the RS4000 is the voltage that is expected. 
Connection of a 115 VAC RS4000  to an 
unexpected 230 VAC line is a common 
occurrence.   This will cause readily 
identifiable board failure that WILL NOT 
BE COVERED UNDER WARRANTY
4.  Manually move the gate to the center of 
the gate opening. 
5.  Make sure the adjustable torque drive 
(ATD) is properly set to just overcome a 
load of slight to moderate force applied to 
the gate. Follow the procedures outlining 
the ATD on Page 17, Section C, if 
readjustment is necessary. 
6.  The proper Left-or Right-hand or Bi-
Parting wiring has been completed. 
7.  The Limit Switch brackets have been 
preliminarily set. 
8.  No other auxiliary devices should be 
connected to the terminal strip until the 
powering-up procedures are completed. 
 
 
 
 
RUNNING THE RS4000
 
Turn ON the main power switch. The gate should not move. If the 
gate moves in either direction or continues to run, turn off the power 
and call Factory Service for assistance.  Follow the instructions 
below for first time commands and the Basic Operation Guide on the 
following  page for ongoing operation. 
 
1.  Give the RS4000 a command to open by touching a jumper wire 
connected to Terminal #16 (COMMON) to Terminal #6 (OPEN). 
The gate should move to the fully open position. 
2.  If the TIMER TO CLOSE option has been enabled, the timer will 
activate the gate to close within the set time parameter on the 
potentiometer.  If not give the RS4000 a command to open by 
touching a jumper wire connected to Terminal #16 (COMMON) 
to Terminal #7 (CLOSE).  
3.  Allow the gate to close and note the position of the gate. 
 
If the gate stops short of the desired fully open or closed position 
or if it bangs against the end stops, TURN OFF THE MAIN 
POWER and reset the appropriate Limit Switch. 
After you have 
attained the final adjustment, run the RS4000 open and closed 
several times to ensure that the positions set will be retained.   
D:
 STARTING THE OPERATOR 
LOCATION OF AUTOCLOSE TIMER
ADJUSTMENT AND SYNCHRONOUS
OPERATION SWITCH
1 2 3
Edge of
Board
Move Jumper to Pins
1 & 2 for Slave Mode
Synchronous Operation
Switch
Figure 19:  Timer Adjustment and Synchronous Switch Location 