MAXIMUM RUN TIMER 
SMART™ Self adjusting MAximum Run Timer (Patent 
Pending) 
 
The RS4000 has a Self adjusting MAximum Run Timer, SMART™ 
(patent pending).  The amount of time for the first few cycles of 
operation are registered and averaged within the motor controller 
circuitry.  After the first few initial cycles, if the gate is activated and 
no other command is given or an end limit (open or close) is not 
reached in the previously counted cycle time plus approximately 4 
seconds, the operator will be turned off.  
 
 
FINAL SETTING OF THE CLOSE TIMER 
To alter the amount of time that the Close Timer will hold the gate 
open, adjust the timer potentiometer located on the control board. 
See Figure 19. 
The Close Timer is adjustable from 2 to approximately 60 seconds. 
Turning the potentiometer clockwise increases the delay; turning it 
counterclockwise decreases the delay. 
D:
 STARTING THE 
You are now ready to install and connect the auxiliary 
equipment. INSTALLATION STEPS DETAILED IN 
SECTIONS A, B, C AND D MUST BE COMPLETE 
BEFORE PROCEEDING. 
 
1.  Vehicle Detectors:  If a Vehicle Detector (Safety Loop) 
is to be a part of this installation, start with this first. 
Connect the Vehicle Detector to AC power and the Loop 
in accordance with the Manufacturer's instructions and 
the information contained in this manual. Do not 
connect to the terminal strip of the RS4000 at this time. 
Test the Vehicle Detector independently using the 
presence lamp on the front panel of the detector and a 
metal plate over the loop. When you are satisfied that 
the Detector is working properly, connect the output 
wires to the "REVERSING" terminal on the control 
panel of the RS4000. 
Give the gate an open command and allow the Timer to 
Close to start the gate to close. Place the metal plate 
over the Loop and observe that the gate reopens. 
 
2.  Shadow Loop:  See Section B regarding Vehicle 
Detector Loop Blanking for Swing Gates. 
3.  Free Exit:  If a "FREE EXIT" Detector is installed, connect the 
output wires of this Detector to the Terminal #5 (FREE EXIT).  
It is acceptable to have more than one device connected to the 
same Terminal.  Place the metal plate over the FREE EXIT 
LOOP and observe that the gate opens to the fully open 
position. Leave the metal plate on the loop for at least one 
minute. Observe that the gate does not close. Remove the plate 
from the Loop and observe that the gate closes.  (Some Vehicle 
Detectors will "tune out" a constant obstruction to the loop after 
15 to 30 minutes.) 
4.  Installing other entry devices:  After you are satisfied that all 
the loops are functioning properly, proceed with the installation 
of the additional devices, such as a Radio Receiver, Telephone 
Entry or Key Pad. Connect the Radio Receiver to the Radio 
Terminal. Observe the precautions regarding radio receivers 
described on page 15. Other entry devices MUST be connected 
to the appropriate terminal (See pages 15 & 16 for terminal 
descriptions). The recommended minimum distance between the 
gate or fence and an accessory input device is 10 feet. 
E:
 INSTALLATION NOTES FOR AUXILIARY EQUIPMENT 
BASIC OPERATIONAL GUIDE 
 
If the gate is fully closed an Open Button, Alternate, Radio or Free 
Exit input will cause the gate to begin moving in the open direction. 
If the gate is fully open a Close Button, Alternate, or Radio input 
will cause the gate to begin moving in the close direction. 
If the gate is moving in a Close direction a Close Non-Contact 
Sensor or a Close Contact Sensor input will cause the gate to stop, 
pause and reverse for approximately 2 inches in the Open direction. 
If the gate is moving in a Close direction an Open Button, Radio, 
Reversing, or Free Exit Loop input will cause the gate to stop, pause 
and reverse and run in the Open direction. 
If the gate is moving in a Close direction a Stop Button or Alternate 
input will cause the gate to stop.  A subsequent Alternate input will 
cause the gate to begin moving in the Open direction. 
 
 
If the gate is moving in an Open direction an Open Non-Contact 
Sensor, Open Contact Sensor input or an Open Overload activation 
will cause the gate to stop, pause and reverse for approximately 2 
inches in the Open direction. 
If the gate is moving in an Open direction a Stop or Alternate input 
will cause the gate to stop.  A subsequent Alternate input will cause 
the gate to begin moving in the Close direction. 
 
MANUAL OPERATION FEATURE:
  The gate can be moved 
open or close in case of power failure or other need to move the gate 
manually from any position except fully closed without disconnecting the 
operator arm.  Remove power from the unit (if not already off) and firmly 
grasp the leading edge of the gate.  Push or pull the gate in the direction 
desired.  The amount of force required to move the gate will depend on the 
setting of the adjustable torque drive, the gate weight,  and the inherent 
friction of the overall system. Manual Operation is to be attempted only 
when the operator is not moving under power. 
 
F:
 END USER INSTRUCTIONS 
GATE OPENER OPERATION AND SAFETY 
IMPORTANT SAFETY INSTRUCTIONS. TO REDUCE THE RISK OF SEVERE INJURY OR 
DEATH: READ AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL! 
WARNING!