DSCover Satellite Products Home Security System PC1555MX Benutzerhandbuch

Seite von 52
42
Appendix A: Reporting Codes
The following tables contain Contact ID and Automatic SIA for-
mat reporting codes. For more information on reporting code
formats and notes about individual reporting codes, see sec-
tions 5.8 
Contact ID
The first digit (in parentheses) will automatically be sent by the
control. The second two digits are programmed to indicate spe-
cific information about the signal.
For example, if zone 1 is an entry/exit point, you could program
the event code as [34]. The central station would receive the
following:
*BURG - ENTRY/EXIT - 1
where the “1” indicates which zone went into alarm.
SIA Format - Level 2 (Hardcoded)
The SIA communication format used in this product follows the
level 2 specifications of the SIA Digital Communication Stan-
dard - January 1996. This format will send the Account Code
along with its data transmission. The transmission would look
similar to the following at the receiver:
N  Ri01
BA  01
N
= New 
Event
Ri01 
Partition /Area Identifier
BA
= Burglary 
Alarm
01
= Zone 
1
Section #
Reporting Code
Code Sent When...
Dialer 
Direction*
Automatic 
Contact ID 
Codes
SIA Auto Rep 
Codes**
[320]
Zone Alarms
zone goes into alarm
A/R
(1) 3A
See  Table 3
[324]
Zone Restorals
alarm condition has been restored
A/R
(1) 3A
[330]
[334]
Zone Tamper/Restoral
zone exhibits a tamper condition/tamper condition 
restored
T/R
(1) 44
TA-ZZ/TR-ZZ
[328]
Duress Alarm
duress code entered at keypad
A/R
(1) 21
HA-00
[328]
Opening After Alarm
system disarmed with alarm in memory
A/R
(4) A6
OR-00
[328]
Recent Closing
alarm occurs within two minutes of system arming
A/R
(4) 59
CR-00
[328]
Zone Expander Supervi-
sory Alarm/Rest.
panel loses/restores supervisory transmission over the 
Keybus from enrolled PC5132 module or keypads with 
zone inputs
A/R
(1) 43
UA-00/UH-00
[328]
Cross Zone (Police Code) 
Alarm
two zones on the same partition go into alarm during 
any given armed-to-armed period (incl. 24Hr zones)
A/R
(1) 4A
BV-00
[329]
[F] Key Alarm/Rest.
Keypad fire alarm (alarm and restore rep. codes sent 
together)
A/R
(1) 15
FA-00/FH-00
[329]
[A] Key Alarm/Rest.
Keypad auxiliary alarm (alarm and restore rep. codes 
sent together)
A/R
(1) AA
MA-00/MH-00
[329]
[P] Key Alarm/Rest.
Keypad panic alarm (alarm and restore rep. codes sent 
together)
A/R
(1) 2A
PA-00/PH-00
[329]
PGM2 Alarm/Rest.
a panic button wired to PGM2 is pressed / access code 
is entered (PGM2 programmed as option [23] or [24])
A/R
(1) 4A
UA-99/UH-99
a 2-wire smoke detector wired to PGM2 goes into alarm/
alarm is cleared (PGM2 programmed as option [04])
A/R
(1) 11
FA-99/FH-99
[338]
General System Tamper/
Rest.
enrolled module with tamper inputs has a tamper alarm/
all module tampers restored
T/R
(1) 45
TA-00/TR-00
[338]
Keypad Lockout
max. number of incorrect access codes has been 
entered at a keypad
T/R
(4) 21
JA-00
[339-343]
Closings
system armed (user 01-34, 40-42 indicated)
O/C
(4) A2
CL-UU
[343]
Partial Closing
one or more zones bypassed when system armed
O/C
(4) 7A
CG-ZZ
[343]
Special Closing
Closing (arming) using one of the following methods: 
quick arm, auto arm, keyswitch, function key, mainte-
nance code, DLS software
O/C
(4) AA
CL-00
[344-348]
Openings
system disarmed (user 01-34, 40-42 indicated)
O/C
(4) A2
OP-UU
[348]
Auto Arm Cancellation
auto arm cancelled
O/C
(4) A5
CE-00
[348]
Special Opening
Opening (disarming) using one of the following meth-
ods: keyswitch, maintenance code, DLS software
O/C
(4) AA
OP-00
[349-350]
Battery Trouble/Rest.
PC1555MX battery is low/battery restored
MA/R
(3) A2
YT-00/YR-00
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
** UU = user number (user01-42); ZZ = zone number (01-32)
WWW.DIYALARMFORUM.COM