DSCover Satellite Products Home Security System PC1555MX Benutzerhandbuch

Seite von 52
43
Table2: Contact ID Zone Alarm/Restoral Event 
Codes (as per ADEMCO):
Program any of these codes for zone alarms/restorals when using
the standard (non-automatic) Contact ID reporting format.
Table 3: SIA Format Automatic Zone 
Alarm/Restoral Codes
Section #
Reporting Code
Code Sent When...
Dialer 
Direction*
Automatic 
Contact ID 
Codes
SIA Auto Rep 
Codes**
[349-350]
AC Line Trouble/Rest.
AC power to control panel is disconnected or inter-
rupted/AC power restored (Both codes follow AC Fail-
ure Comm. Delay.)
MA/R
(3) A1
AT-00/AR-00
[349-350]
Main Bell Trouble/Rest.
open circuit detected across bell terminals/bell circuit 
closed
MA/R
(3) 21
UT-99/UJ-99
[349-350]
Fire Trouble/Rest.
a trouble occurs/restores on a fire zone
MA/R
(3) 73
FT-00/FJ-00
[349-350]
Auxiliary Power Trouble/
Rest.
aux voltage supply trouble/restoral
MA/R
(3) AA
YP-00/YQ-00
[349]
TLM Failure
telephone line monitoring trouble (sent via LINKS. Do 
not program if LINKS not used)
MA/R
(3) 51
LT-00
[350]
TLM Restore
Telephone line trouble restore
MA/R
(3) 51
LR-00
[349-350]
Gen System Trouble/Rest.
“Service Required” trouble occurs (view troubles using 
[*][2])/trouble restored
MA/R
(3) 33
ET-00/ER-00
[349-350]
Gen System Supervisory 
Trouble/Rest.
control panel loses/restores communications with  mod-
ule(s) connected to the Keybus
MA/R
(3) 33
ET-00/ER-00
[351]
Line 1 or 2 FTC Restoral
control panel has restored communications to central 
station on line 1 or 2 (after FTC)
MA/R
(3) 54
YK-00
[351]
Event Buffer is 75% Full
event buffer is almost full since last upload
MA/R
(6) 23
JL-00
[351]
DLS Lead In
downloading session start
MA/R
(4) 11
RB-00
[351]
DLS Lead Out
downloading session complete
MA/R
(4) 12
RS-00
[351]
Zone Fault/Rest.
one or more zones have faults/restored
MA/R
(3) 72
UT-00/UJ-00
[351]
Delinquency
programmed amount of time (days or hours) for delin-
quency has expired without zone activity or without sys-
tem being armed
MA/R
(4) 54***
CD-00
[352]
Periodic Test
periodic system test transmission  
T
(6) A2
RP-00
[352]
System Test
[*][6] bell/communications test
T
(6) A1
RX-00
[352]
LINKS Test
LINKS test transmission
T
(6) A3
TX-00
[353]
Wireless Device Low Bat-
tery Trouble/Rest.
wireless zones (WLS904, WLS905, WLS907); panic
pendants (WLS908); handheld keypads (WLS910);
wireless keys (WLS909) have low battery/all low batter-
ies restored
MA/R
(3) 84
XT-00/XR-00
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
** UU = user number (user01-42); ZZ = zone number (01-32)
***Program the “Fail to close” event code [(4)54] to report either closing or activity delinquency.
Make sure your central station is aware of the application of this reporting code.
Medical Alarms 
(1)34  Entry / Exit
(1)AA  Medical
(1)35  Day / Night
(1)A1  Pendant Transmitter
(1)36  Outdoor
(1)A2  Fail to Report In
(1)37  Tamper
Fire Alarms
(1)38  Near Alarm
(1)1A  Fire Alarm
General Alarms
(1)11  Smoke
(1)4A  General Alarm
(1)12  Combustion
(1)43  Exp. module failure
(1)13  Water Flow
(1)44  Sensor tamper
(1)14  Heat
(1)45  Module Tamper
(1)15  Pull Station
(1)4A  Cross Zone Police Code
(1)16  Duct
24 Hour Non-Burglary
(1)17  Flame
(1)5A  24 Hour non-Burg
(1)18  Near Alarm
(1)51  Gas detected
Panic Alarms
(1)52  Refrigeration
(1)2A  Panic
(1)53  Loss of Heat
(1)21  Duress
(1)54  Water Leakage
(1)22  Silent
(1)55  Foil Break
(1)23  Audible 
(1)56  Day Trouble
Burglar Alarms
(1)57  Low bottled Gas level
(1)3A  Burglary
(1)58  High Temp
(1)31  Perimeter
(1)59  Low Temp
(1)32  Interior
(1)61  Loss of Air Flow
(1)33  24 Hour
Zone Definition
SIA Auto Rep 
Codes*
Zone Alm/Rest.
Delay, Instant, Interior, Delay 
Stay/Away, Interior Stay/Away, 
24Hr Burg.
BA-ZZ/BH-ZZ
Standard 24Hr Fire, Delayed 
24Hr  Fire
FA-ZZ/FH-ZZ
24Hr Supervisory
US-ZZ/UR-ZZ
24Hr Supervisory Buzzer
UA-ZZ/UH-ZZ
24Hr Sprinkler
SA-ZZ/SH-ZZ
24Hr Gas
GA-ZZ/GH-ZZ
24Hr Heat
KA-ZZ/KH-ZZ
24Hr Medical
MA-ZZ/MH-ZZ
24Hr Emergency (non-medical)
QA-ZZ/QH-ZZ
24Hr Waterflow
WA-ZZ/WH-ZZ
24Hr Freeze
ZA-ZZ/ZH-ZZ
24Hr Holdup
HA-ZZ/HH-ZZ
24Hr Panic
PA-ZZ/PH-ZZ
Latching 24Hr 
BA-ZZ/BH-ZZ
* ZZ = zones 01-32
WWW.DIYALARMFORUM.COM