Maytag PGC2MQ iQ Drive | Maytag M1200 97% AFUE Modulating Gas Furnace Technisches Handbuch
6
SPECIFICATIONS
PGC2MQ MODEL
NUMBERS:
060DVB
080DVC
100DVC
120DVD
Input - Btuh (a)
60,000 / 30,000
80,000 / 40,000
100,000 / 50,000 120,000 / 60,000
Heating Capacity - Btuh
58,200 / 29,100
77,600 / 38,800
97,000 / 48,500
116,400 / 58,200
AFUE
97.0
97.2
97.4
97.0
Blower D x W
11 x 8
11 x 10
11 x 10
11 x 10
Motor H.P. - Speed - Type
1/2 - Variable
3/4 - Variable
3/4 - Variable
1 - Variable
Motor FLA
6.2
8.7
8.7
11.70
Rated Ext. SP - In. W.C.
0.5
0.5
0.5
0.5
Temperature Rise Range - ºF
30-60
35-65
35-65
40-70
Shipping Weights
130lbs
140lbs
150lbs
165lbs
NOTE: All models are 115V, 60 Hz. Gas Connections are 1/2" N.P.T. AFUE = Annual Fuel Utilization Efficiency
(a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.
(a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.
AIRFLOW DATA
Gas Input
Rate
(Btuh)
Target CFM for Selected Circulating Air
Temperature Rises, F
45
50
55
60
Constant
Full
Input
Minimum
Input
Full
Input
Minimum
Input
Full
Input
Minimum
Input
Full
Input
Minimum
Input
60,000
1,110
635
1,000
560
940
515
850
470
950
80,000
1,480
850
1,345
740
1,255
685
1,140
625
1,300
100,000
1,850
1,050
1,680
925
1,565
855
1,460
780
1,760
120,000
2,225
1,270
2,020
1,115
1,890
1,025
1,730
940
2,100
NOTE: This table lists the High and Low target CFMs for each maximum input rate and temperature rise. If the
target CFM is more that 1,600 CFM, it is recommended that two return air openings into the furnace be used.
NOTE: The blower operating range is .1” to .8” ESP in wc.
target CFM is more that 1,600 CFM, it is recommended that two return air openings into the furnace be used.
NOTE: The blower operating range is .1” to .8” ESP in wc.
Description
Sku
iQ Controller kit
920620*
* Revision Letter
iQ CONTROLLER KIT