Cabinet and Countertop Layout
 WARNING
•  Failure to meet or exceed the maximum and mini-
mum dimensions/clearances stated in these instruc-
tions may result in a fire hazard.
•  Follow the countertop manufacturer’s instructions 
regarding the minimum corner radius, use of heat 
reflective tape, reinforcement of corners, etc.
•  Carefully check the location where the cooktop will be 
installed. For best performance, the cooktop should be 
placed away from drafts that may be caused by doors, 
windows and heating and air conditioning outlets. 
•  This appliance is to be used in conjunction with a suit-
able vent hood.
(A) Minimum
(A) Recommended
36” (91.4 cm)
42” (106.7 cm)
Installation Specifications
•  Allow a minimum ¼” (6 mm) clearance between the 
bottom of the cooktop chassis and all combustible sur-
faces, including the upper edge of a drawer installed 
below the cooktop.
Under Cabinet Clearances
•  The gas supply piping, gas shut-off valve and the elec-
trical outlet must be located so that they do not inter-
fere with the cooktop when it is installed. If installing 
another appliance in the cabinet below, allow for the 
routing of gas and electrical service behind it.
The installation must allow for the following:
•  Access to the gas shut-off valve and regulator when 
the unit is installed. 
•  Access to the electrical outlet when the cooktop is in 
place. The 42” (106.7 cm) power cord must be able to 
reach the electrical outlet.
•  Access to the underside of the cooktop for service and 
inspection purposes.
•  Clearance inside the cabinet to allow for proper hold 
down bracket installation.
To allow access to the utilities and cooktop bottom, a fixed 
shelf should not be installed below the cooktop. See the fol-
lowing pages for countertop cutout dimensions.
¼” (6 mm)
mimimum clearance
to combustible
surfaces
 35 ¼” (89.5 cm)*
 * Allows for clearance between hold down brackets
13" max.
3
(33.0 cm)
3
 Not applicable for cabinets more than a horizontal distance of  
  
 
5 ½” (14.0 cm) from edge of cooktop. Allow 6 
7
/
8
” (17.5 cm) 
  
 
from cutout edge.
A
  18" min.
1, 3
(45.7 cm)
 1 
5
/
8
" min. 
(4.1 cm)
Combustible 
surface to rear
Combustible overhead 
cabinets
30" min.
1, 2
(76.2 cm)
See cutout dimensions
See cutout
dimensions
2
 If installing with an overhead vent hood, also check the hood 
  
 
specifications for minimum required clearances.
1
 Measured from the cooking surface (top of cooktop grate).
All tolerances +1/16” (+1.6 mm), -0 
unless otherwise noted.
Minimum Required Clearances Around the Cooktop