Put power supply cord through the strain relief. Be sure that 
the wire insulation on the power supply cord is inside the 
strain relief. The strain relief should have a tight fit with the 
dryer cabinet and be in a horizontal position. Do not further 
tighten strain relief screws at this point.
For 3-wire Power Supply Cord Connection.
For 4 wire Power Supply Cord Connection, continue to 
step 3.
Attach power supply cord  
to strain relief
2.
D
C
B
A
   
 
Attach power supply cord  
     strain relief
Remove the screws from a 3/4" (19 mm) UL listed strain relief 
(UL marking on strain relief). Put the tabs of the two clamp 
sections (C) into the hole (B) below the terminal block opening 
so that one tab is pointing up (A) and the other is pointing 
down (D), and hold in place. Tighten strain relief screws just 
enough to hold the two clamp sections (C) together.
1.
Power supply cord strain relief
POWER SUPPLY CORD CONNECTION
4-wire Power Supply Cord Connection
Remove center terminal block screw (B). Remove neutral 
ground wire (E) from external ground conductor screw (A).
B
A
E
Prepare to connect neutral  
ground wire and neutral wire.
3.
IMPORTANT: 
A 4-wire connection is required for mobile 
homes and where local codes do not permit the use of 3-wire 
connections. 
A.  4-wire receptacle (NEMA type 14-30R)
B.  4-prong plug
C.  Ground prong
D.  Neutral prong
E.  Spade terminals with upturned ends
F.  3/4" (19 mm) UL listed strain relief
G.  Ring terminals
B
C
E
Connect neutral ground wire 
and neutral wire
4.
Connect neutral ground wire (E) and neutral wire (white or 
center) (C) of power supply cord under center terminal block 
screw (B). Tighten screw.
A
F
Connect ground wire (F) (green or bare) of power supply cord  
to external ground conductor screw (A). Tighten screw.
5.
 
Connect ground wire
A.
B.
D.
C.
E.
F.
G.