Verifying the Package Contents
• Use and Care Manual
• Anchoring Legs
Installation Planning
A qualified technician must complete the 
installation of this appliance. Proper installation 
is your responsibility.
Raised Vent System Specifications
Raised Vent 
Model No.
For Use with
For Use with Blower
Duct Size
ERV/PRV30
30” Ranges/Cooktops
REMP3/16
3 1/4”x10”, 8” & 10”
ERV/PRV36
36” Cooktops
REMP3/16
3 1/4”x10”, 8” & 10”
PRV46
46” Cooktops
REMP3/16
3 1/4”x10”, 8” & 10”
ERV48
48” Cooktops
REMP3/16
3 1/4”x10”, 8” & 10”
For detailed information on the remote blowers, refer to the Remote Blowers Installation Instructions.
Duct Planning
wARNINgS
1.  To reduce the risk of fire and 
to properly exhaust air, ducted 
fans must be vented to outside. 
Do not vent exhaust air into 
spaces within walls, ceilings, 
attics, crawl spaces or garages.
2.  Improper installation, 
adjustment, alteration, service, 
or maintenance can cause 
personal injury or property 
damage.
3.  To reduce the risk of fire, 
use only ductwork materials 
deemed acceptable by state, 
municipal and local codes.
wARNINg: 
Failure to disconnect power may 
result in electrical shock or fire 
hazard! If the electric service 
provided does not meet the 
product specifications, do not 
proceed with the installation. Call 
the selling dealer or a licensed 
electrician.
Electrical Power Supply 
Requirements
It is the owner’s responsibility to ensure that 
the electrical connection of this appliance 
is performed by a qualified electrician. The 
electrical installation, including minimum supply 
wire size and grounding, must be in accordance 
with the National Electric code ANSI/NFPA 70-
2002* (or latest revision) and local codes and 
ordinances. 
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101 
The correct 120VAC, 60Hz, 15A circuit must 
be supplied for this appliance from a separate, 
grounded, circuit that is protected by a properly 
sized circuit breaker or time delay fuse.
NOTES:
1.  Best performance is achieved 
by using round duct instead of 
rectangular, especially when 
elbows are required.  
2.  If multiple elbows are needed, 
ensure that there is a minimum 
of 24” of straight duct between 
any two elbows. 
3.  Avoid “S” or “back to back” 
configurations caused by 
adjacent elbows. 
8 1/2"
(216mm)
6 5/8”
(168mm)
10"
(254mm)
30"
(762mm)
18 13/16”
(478mm)
1 7/8" x 16"
Exhaust duct
Stiffener
3 3/4"
(95mm)
3/4" (19mm)
Finished floor
1 7/8" x 16"
Exhaust duct
3 1/4" x 10" 
Rear 
Exhaust duct
1 7/8" x 16"
Exhaust duct
1 7/8" x 16"
Exhaust duct
48", 3 prong 
grounded
power cord
Electrical
access panel
3/8"
(10mm)
Countertop
Motor
cover
6"
(152mm)
3 1/4" x 10"
Exhaust duct
25 7/8"
(657mm)
2 13/16"
(71mm)
Cooktop/Range
Stud wall
Wall board
3/4"  (19mm) Max. backsplash thickness
1/4" (6mm) Min. flat area
3"
(76mm)
9/32" (7mm)
1 15/16"
(49mm)
2 1/8"
(54mm)
B
A
ERV Overall Dimensions
Side View
ERV Overall Dimensions
Front View
Model
width “A”
width “B”
ERV/PRV30
30” (762mm)
27 3/4” (705mm)
ERV/PRV36
36” (914mm)
33 3/4” (857mm)
PRV46
46” (1168mm)
43 3/8” (1102mm)
ERV48
48” (1219mm)
43 3/8” (1102mm)
Overall Dimensions