Countertop and Cabinet Preparation 
wARNINgS:
1.  To reduce the risk of personal 
injury caused by reaching 
over a hot appliance, cabinet 
storage space located directly 
above the cooktop should be 
avoided.
2.  Do not store combustible 
materials or items adversely 
affected by heat in cabinet 
areas above the appliance.
3.   Follow the instructions 
regarding minimum safe 
clearances and installation 
location. Failure to do so may 
result in a fire or safety hazard.
Plan the installation so that all required minimum 
clearances between the cooktop, overhead 
cabinets and adjacent vertical walls are 
provided. Refer to the cooktop/range installation 
instructions for the minimum dimensions specific 
to the particular appliance being installed.
The DACOR Raised Vent System is designed 
to remove the contaminants and by-products 
that result when cooking with gas or electric 
appliances. The vent system consists of the vent 
intake along with a remote blower. The raised 
vent downdraft systems are compatible for 
use with select DACOR cooktops and ranges, 
therefore, these instructions offer specific 
guidelines for mounting the raised vents behind 
DACOR cooktops and ranges.
27 13/16"
(706mm)
29 1/4" (743mm)
13/32" (10mm)
30 1/16" (764mm)
Countertop overhangs cabinet
6" (152mm) Min.
to combustible side
walls above the range
(both sides)
27 7/8" (708mm)
Adjust for backsplash
over 3/4" thick
from 13/16" to 3 13/16" 
(21 - 97mm)
Backsplash
thicker than
3/4" (19mm)
1/4" (6mm)
Min. flat ledge
Vertical
non-combustible
surface rear wall
2 13/16"
(71mm)
21 3/8"
(543mm)
28 3/16"
(716mm)
ESG366 - 34 3/4" (883mm)
ESG486 - 46" (1168mm)
5/8" (16mm)
ESG366 - 36" (914mm)
ESG486 - 48" (1219mm)
6" (152mm) Min.
to combustible side
walls above the range
(both sides)
ERV36 -33 7/8" (860mm)
ERV48 - 43 1/2" (1105mm)
3" (76mm)
Backsplash
Max.3/4" (19mm)
1/4" (6mm)
Min. flat ledge
Vertical
non-combustible
surface rear wall
2 13/16"
(71mm)
27 13/16"
(706mm)
29 1/4" (743mm)
13/32" (10mm)
30 1/16" (764mm)
Countertop overhangs cabinet
6" (152mm) Min.
to combustible side
walls above the range
(both sides)
Vertical
non-combustible
surface rear wall
3/4" (19mm)
Max. backsplash
1/4" (6mm)
Min. flat ledge
13/16" (21mm)
23 3/16"
(589mm)
27 7/8" (708mm)
2 13/16"
(71mm)
ERV/PRV30 with Epicure 30” Range
Slide-In, Self-Rimming Installation
with Side Panels and Backguard Removed
Top View
ERV/PRV30 with Preference 30” Range
Slide-In, Self-Rimming Installation
using 3” Side Panels, Backguard Removed
Top View
ERV with Epicure Cooktops
Top View
Finished floor
3 1/4" x 10"
90° Elbow
ERV30
Motor cover
3 1/4" x 10"
Duct
Epicure 30
Range
ERV30/
PRV30
Wall board
Stud wall
Backsplash
REMP3/16
3 1/4" x 10" to Round
transition 8” or 10” DIA.
Anchoring leg
ERV/PRV Against Wall Installation
with REMP3/16 on the Roof